Torsional stability of interference screws derived from bovine bone - a biomechanical study
نویسندگان
چکیده
BACKGROUND In the present biomechanical study, the torsional stability of different interference screws, made of bovine bone, was tested. Interference screws derived from bovine bone are a possible biological alternative to conventional metallic or bioabsorbable polymer interference screws. METHODS In the first part of the study we compared the torsional stability of self-made 8 mm Interference screws (BC) and a commercial 8 mm interference screw (Tutofix). Furthermore, we compared the torsional strength of BC screws with different diameters. For screwing in, a hexagon head and an octagon head were tested. Maximum breaking torques in polymethyl methacrylate resin were recorded by means of an electronic torque screw driver. In the second part of the study the tibial part of a bone-patellar tendon-bone graft was fixed in porcine test specimens using an 8 mm BC screw and the maximum insertion torques were recorded. Each interference screw type was tested 5 times. RESULTS There was no statistically significant difference between the different 8 mm interference screws (p = 0.121). Pairwise comparisons did not reveal statistically significant differences, either. It was demonstrated for the BC screws, that a larger screw diameter significantly leads to higher torsional stability (p = 9.779 x 10(-5)). Pairwise comparisons showed a significantly lower torsional stability for the 7 mm BC screw than for the 8 mm BC screw (p = 0.0079) and the 9 mm BC screw (p = 0.0079). Statistically significant differences between the 8 mm and the 9 mm BC screw could not be found (p = 0.15). During screwing into the tibial graft channel of the porcine specimens, insertion torques between 0.5 Nm and 3.2 Nm were recorded. In one case the hexagon head of a BC screw broke off during the last turn. CONCLUSIONS The BC screws show comparable torsional stability to Tutofix interference screws. As expected the torsional strength of the screws increases significantly with the diameter. The safety and in vivo performance of products derived from xenogeneic bone should be the focus of further investigations.
منابع مشابه
Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملAn intramedullary Echidna pin for fixation of comminuted clavicle fractures: a biomechanical study
BACKGROUND Intramedullary fixation of comminuted mid-shaft clavicle fractures has traditionally been employed with satisfactory clinical outcomes; however, pins with smooth surfaces may protrude from the bone and are prone to migration, while some threaded pins are difficult to remove post-operatively. The aim of this proof-of-concept study was to develop and evaluate the biomechanical strength...
متن کاملPrimary stability of bone-patellar tendon-bone graft fixation with biodegradable pins.
PURPOSE We evaluated the initial bone-patellar tendon-bone (BPTB) graft fixation strength of biodegradable pins compared with interference screws in anterior cruciate ligament reconstruction using bovine knees. TYPE OF STUDY Biomechanical in vitro study. METHODS Ten BPTB grafts from human donors fixed with 2 biodegradable 2.7-mm pins (Rigid Fix; Ethicon, Mitek Division, Norderstedt, Germany...
متن کاملBiomechanical and Histological Evaluation of Roughened Surface Titanium Screws Fabricated by Electron Beam Melting
BACKGROUND Various fabrication methods are used to improve the stability and osseointegration of screws within the host bone. The aim of this study was to investigate whether roughened surface titanium screws fabricated by electron beam melting can provide better stability and osseointegration as compared with smooth titanium screws in sheep cervical vertebrae. METHODS Roughened surface titan...
متن کاملBiomechanical Performance of Various Cement-Augmented Cannulated Pedicle Screw Designs for Osteoporotic Bones.
INTRODUCTION Early-stage pullout is a common problem for surgeons during the fixation of osteoporotic bones. Poor bone quality limits the use of pedicle screws for patients with osteoporosis. In this study, the researchers investigated the effects of hole and gap position and type on the pullout strength of cannulated screws. METHODS Seven different designs were tested, including a control gr...
متن کامل