Application of Minimum Effective Cuff Inflating Volume for Laryngeal Mask Airway and its Impact on Postoperative Pharyngeal Complications

نویسندگان

  • Bing-Bing Li
  • Jie Yan
  • Hong-Gang Zhou
  • Jing Hao
  • Ai-Jia Liu
  • Zheng-Liang Ma
چکیده

BACKGROUND High intracuff pressure can cause severe pharyngeal complications including sore throat or hoarseness after laryngeal mask airway (LMA) removal postoperatively. Though the application of minimum effective cuff inflating volume is suggested to maintain airway sealing and adequacy of ventilation for patients receiving general anesthesia with LMA at lower level of the intracuff pressure, it is currently not a standard care in most of the anesthetic departments. In this study, the minimum effective cuff inflating volume was determined for classic LMA Well Lead™ (Well Lead Medical Co., Ltd., China) and its impact on postoperative pharyngeal complications was also explored. METHODS Patients with American Society of Anesthesiologists physical status (I-III) undergoing the short-duration urological surgery were recruited in this trial. First, the minimum effective cuff inflating volume was determined for size 4 or 5 LMA Well Lead in the study 1. Immediately following placement and confirmation of ideal LMA position, the cuff was inflated with 5, 7, 10 ml of air and up to 30 ml at 5 ml increment. The intracuff pressure, oropharyngeal leak pressure (OLP), and inspiratory peak airway pressure under positive pressure ventilation at the corresponding cuff volume as indicated above were recorded. Second, the enrolled patients were randomly allocated into minimum effective cuff inflating volume group (MC) and routine care (RC) group in the study 2. The minimum effective cuff inflating volume was applied and maintained in MC group, whereas the cuff volume was inflated with half of the maximum cuff inflating volume recommended by manufacturer in RC group throughout the surgical procedure and stay in postanesthesia care unit prior to LMA removal. The incidence of pharyngeal complications at 0, 2, 24, and 48 h after removal of LMA and other intra-operative adverse events were also documented. RESULTS The intracuff pressure varied with the cuff inflating volume in a positive linear correlation manner (Y = 11.68X - 42.1, r(2) = 0.9191) under the range of 5-30 ml for size 4 LMA. In similar with size 4 LMA, the data were also showed the linear relationship between the intracuff pressure and the cuff inflating volume (Y = 7.39X - 10.9, r(2) = 0.8855) for size 5 LMA. The minimal effective cuff inflating volume for size 4 or 5 LMA was 7-9 ml in combination of considering OLP needed to maintain airway sealing during intermittently positive pressure ventilation. The intracuff pressure in MC group was lower compared with RC group (63.0 ± 3.7 vs. 126.4 ± 24.0 cmH2O for size 4 LMA; 55.6 ± 2.4 vs. 138.5± 26.8 cmH2O for size 5 LMA; P < 0.0001). The incidence of pharyngeal adverse events was lower in MC group versus the RC group at 2, 24 h after LMA removal. CONCLUSIONS The relationship between the cuff inflating volume and the intracuff pressure for size 4 or 5 LMA Well Lead(TM) is in a linear correlation manner at the range of 5-30 ml. The minimal cuff inflating volume is adequate for satisfactory airway sealing and consequently associated with lower incidence of postoperative pharyngeal complications for LMA Well Lead.™.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Limitation of Laryngeal Mask Airway Usage in Open-Neck Procedure

I read the manuscript entitled “Case Report of An Open Neck Procedure Complication Associated with Laryngeal Mask Airway Use” by Subramaniam T et al. This is a valuable manuscript describing iatrogenic complications during level-2 cervical lymph node biopsy, in which the airway is managed with laryngeal mask airway (LMA). During the procedure, the surgeon realized that the mass was actually the...

متن کامل

مقایسه اثر استفاده از ماسک حنجره (Laryngeal mask airway) و لوله کافدار حلقی (Cuffed pharyngeal tube) در بروز گلودرد پس از بیهوشی عمومی در بزرگسالان

Post-operative sore throat is one of the most common complications and complaints of patients after general anesthesia especially in operations that need endotracheal intubations. Its causes are: size of endotracheal tube and type of its cuff, inadequate airway humidification, trauma during intubation and suctioning, high flow of inspiratory gases, surgical manipulation of airway and adjacent o...

متن کامل

Case Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use

Introduction: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication.   Case Report...

متن کامل

Comparison of mucosal pressures induced by cuffs of different airway devices.

BACKGROUND High pressures exerted by balloons and cuffs of conventional endotracheal tubes, the Combitube (Tyco Healthcare Nellcor Mallinckrodt, Pleasanton, CA), the EasyTube (Teleflex Ruesch, Kernen, Germany), the Laryngeal Mask Airway (LMA North America, San Diego, CA), the Intubating Laryngeal Mask Airway (Fastrach; LMA North America), the ProSeal (LMA North America), and the Laryngeal Tube ...

متن کامل

The laryngeal mask airway: a comparison between two insertion techniques.

UNLABELLED The purpose of the study was to compare the ease of insertion of the laryngeal mask airway using the standard uninflated approach or with a fully inflated cuff. Two hundred consecutive patients undergoing anesthesia using a laryngeal mask airway were randomized to have the laryngeal mask inserted using either method. Successful insertion was judged primarily by the clinical function ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 128  شماره 

صفحات  -

تاریخ انتشار 2015