Interferences of suspended clay fraction in protein quantitation by several determination methods.
نویسندگان
چکیده
Seven current methods of protein quantitation, Bradford (standard, micro, and 590/450 nm ratio), Lowry, bicinchoninic acid (BCA), UV spectrophotometry at 280 nm, and Quant-iT fluorescence-based determination, were compared with regard to their susceptibility to interferences due to the presence of suspended and not easily detectable clay particles. Bovine serum albumin (BSA) and Na-Wyoming montmorillonite were selected as model protein and reference clay, respectively. Protein-clay suspension mixtures were freshly prepared for each assay to simulate supernatants not completely centrifuged in batch sorption/kinetic experiments. Seven fixed increasing levels of clay (0.0, 0.00725, 0.0145, 0.029, 0.058, 0.145, 0.435 mg ml(-1)) were mixed with different levels of BSA in an appropriate range for each assay. To ascertain the interfering effect of different levels of clay, the theoretical concentrations of BSA were plotted against the estimated BSA concentrations of the samples, as obtained from the calibration curve of each method. A correct quantitation of the BSA concentration not influenced by clay would be described by a regression line with slope (b) not significantly different from 1 and an intercept (a) not significantly different from zero. At the lowest clay levels (0.00725 mg ml(-1)) a significant interference was evident for Bradford micro, Bradford 590/450, UV, and fluorescence. The three methods (Bradford standard, Lowry, and BCA) that seemed to show the better performances in the presence of clay after this first screening step also underwent an ANCOVA analysis, with the measured BSA concentrations as dependent variable and the clay concentrations as covariate. The Bradford standard and BCA methods were affected by a clay-dependent interference on BSA quantitation. The Lowry assay was the only method that gave correct estimates of BSA concentrations in the presence of any of the clay levels tested.
منابع مشابه
Capillarys 3 Octa®: Analytical Performance Assessment for HbA1c Quantification
Objective: Determination of HbA1c level is a precious indicator for therapeutic follow-up of patients with type 1 or type 2 diabetes. Our study aimed to evaluate the analytical characteristics of Capillarys 3 Octa® HbA1c measurement by capillary electrophoresis. Materials and Methods: Our study involved 265 venous whole blood specimens repeatability, intermediate fidelity, accuracy, linearity,...
متن کاملFlow cytometry is a promising and rapid method for differentiating between freely suspended Escherichia coli and E. coli attached to clay particles.
AIM A standard procedure does not exist to distinguish between attached and unattached micro-organisms. In this study, we compared two methods to quantify between Escherichia coli attached to clay particles and E. coli freely suspended in solution: flow cytometry (attachment assay and viability assay) and settling (or centrifugation followed by settling). METHODS AND RESULTS Methods were test...
متن کاملSimple, Fast and Reliable Liquid Chromatographic and Spectrophotometric Methods for the Determination of Theophylline in Urine, Saliva and Plasma Samples
In this study, a high-performance liquid chromatographic method (HPLC) and UV spectrophotometric method were developed, validated and applied for the determination of theophylline in biological fluids. Liquid- liquid extraction is performed for isolation of the drug and elimination of plasma and saliva interferences. Urine samples were applied without any extraction. The chromatographic separat...
متن کاملSimple, Fast and Reliable Liquid Chromatographic and Spectrophotometric Methods for the Determination of Theophylline in Urine, Saliva and Plasma Samples
In this study, a high-performance liquid chromatographic method (HPLC) and UV spectrophotometric method were developed, validated and applied for the determination of theophylline in biological fluids. Liquid- liquid extraction is performed for isolation of the drug and elimination of plasma and saliva interferences. Urine samples were applied without any extraction. The chromatographic separat...
متن کاملA modification of Reiber's laser-nephelometric protein determination method interferences of selected substances.
A modification of Reiber's laser-nephelometric protein quantitation method is described. Salts, (zwitterionic) buffers, sugars, chelating and reducing agents do not interfere with this method. Protein quantitation in the presence of Percoll or nonionic detergents yields erroneous results. The method is compared with two modifications of Lowry's protein determination.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical biochemistry
دوره 376 1 شماره
صفحات -
تاریخ انتشار 2008