Commutability limitations influence quality control results with different reagent lots.
نویسندگان
چکیده
BACKGROUND Good laboratory practice includes verifying that each new lot of reagents is suitable for use before it is put into service. Noncommutability of quality control (QC) samples with clinical patient samples may preclude their use to verify consistency of results for patient samples between different reagent lots. METHODS Patient sample results and QC data were obtained from reagent lot change verification records for 18 QC materials, 661 reagent lot changes, 1483 reagent lot change-QC events, 82 analytes, and 7 instrument platforms. The significance of between-lot differences in the results for QC samples compared with those for patient samples was assessed by a modified 2-sample t test adjusted for heterogeneity of QC and patient sample measurement variances. RESULTS Overall, 40.9% of reagent lot change-QC events had a significant difference (P < 0.05) between results for QC samples compared with results for patient samples between 2 reagent lots. For QC results with differences <1.0 SD interval (83.1% of total), 37.7% were significantly different from the changes observed for patient samples. For QC results with differences ≥1.0 SD interval (16.9% of total), 57.0% were significantly different from those for patient samples. CONCLUSIONS Occurrence of noncommutable results for QC materials was frequent enough that the QC results could not be used to verify consistency of results for patient samples when changing lots of reagents.
منابع مشابه
Use of the Reflotron system for cholesterol assay in capillary blood, venous blood, and serum--evaluation of accuracy and lot-to-lot reagent comparability.
Since its recalibration in 1987, the Reflotron "dry-chemistry" cholesterol method can produce accurate results. Here we report how cholesterol concentrations in venous blood, plasma, and serum determined with Reflotron compare with values determined for fingerstick samples. When no EDTA is used in the latter, accurate results may meet the WHO/CDC criterion of a maximum bias less than or equal t...
متن کاملSelection of a reference lot of Mueller-Hinton agar.
A collaborative study was undertaken to evaluate the performance of currently marketed Mueller-Hinton agars from seven manufacturers by replicate disk diffusion tests with standard quality control strains. Identification of the manufacturers was concealed, and the resulting data were evaluated for the selection of a physical reagent standard against which the performance of future production lo...
متن کاملStatistical Test for Equivalence in Analysis of Commutability Experiments
DISCUSSION We applied equivalence testing on step (1) of analysis of commutability experiments. Statistical inference in terms of equivalence is commonly used in guidelines of pharmaceutical industry if similarity of two or more processes within predefined limits has to be proven (e.g. (FDA 2001)). In clinical chemistry literature equivalence testing is mentioned (Lung, Gorko et al. 2003) only ...
متن کاملComparative potencies of contemporary generic vancomycin lot: in vitro assay results from nine products and a reference reagent-grade sample.
Numerous studies of generic vancomycin (GV) lots have emerged since the 1980s, casting some doubt on product quality. Publications question the in vivo activity, even when concurrent in vitro and chemical assays meet regulatory guidelines. This study assessed contemporary GV lots by an in vitro assay capable of measuring small variations from target-benchmark (BM) activity. Nine GV lots (Hospir...
متن کاملThe importance of commutability of reference materials used as calibrators: the example of ceruloplasmin.
BACKGROUND Different methods for ceruloplasmin tend to give different results in external quality assessment schemes. During the production of the certified reference material ERM-DA470k/IFCC discrepant measurement results were also found for ceruloplasmin measured with different methods, and consequently the protein could not be certified in the material. METHODS We performed a commutability...