Several optimal discharge pressure correlations for transcritical CO2 heat pump in literature have been discussed in this paper. Most of them are related to the ambient temperature, the evaporation temperature and the gas cooler outlet temperature. A revised optimal discharge pressure model as the function of ambient temperature and water outlet temperature is developed based on earlier experimental results. To validate the model developed and control effect in practical applications, field tests are conducted to evaluate the performance of an air-source transcritical CO2 heat pump water heater in practical application. The results show that the coefficient of performance (COP) can achieve 3.76 in the nominal test condition with 15°C water inlet temperature and 80°C hot water supply temperature. Even when the hot water temperature is higher than 90°C, the COP remains at 3.21 with 20°C dry-bulb temperature and 15°C wet-bulb temperature. Under -15°C low ambient air temperature condition, the COP was 2.19 with the hot-water supply temperature of 60°C. Comparison between the field test results and the model predictions show that the maximum relative error of discharge pressure control was 3.2% in the high temperature of water outlet condition. The overall ATHP system performance based on the revised model and PLC control strategy can meet the requirements in practical applications.
منابع مشابه
Influence of Refrigerant Charge Amount and EEV Opening on the Performance of a Transcritical CO2 Heat Pump Water Heater
Besides compressor rotary speed and parameters of water flowing through gas cooler and evaporator, refrigerant charge amount and electronic expansion valve (EEV) opening are two important parameters that have significant effects on the performance of a transcritical CO2 heat pump system. In this study, the effects of refrigerant charge amount on the performance of a transcritical CO2 heat pump ...
متن کاملExperimental Investigation on the Influence of Refrigerant Charge on the Performance of Trans-critical CO2 Water-Water Heat Pump
For the environmentally aware, natural refrigerant such as CO2 is recommended and pursued by researchers for refrigerators. In this paper, a transcritical CO2 heat pump system was set up to investigate the influence of refrigerant charge on the performance of a small-sized heat pump water heater. The transcritical CO2 heat pump system was composed of a rotary compressor, a tube-in-tube evaporat...
متن کاملExperimental investigation on the influencing factors of a transcritical CO2 heat pump
As one of the earliest natural refrigerants, CO2 has a lot of unique advantages, such as zero ODP, negligible GWP, excellent heat transfer coefficient, high volumetric capacity, non-toxicity, non-flammability, and cost effectiveness. Since it was proposed to applying in the mobile air-conditioning, the transcritical CO2 cycle has been attracting great attentions to replace CFC and HCFC refriger...
متن کاملExperimental Study on the Performance of Water Source Trans-Critical CO2 Heat Pump Water Heater
The effect of the discharge pressure on the performance of the trans-critical CO2 heat pump with a low gas-cooler outlet temperature is experimentally investigated on a test rig of water source heat-pump water heater. The optimal discharge pressure of the trans-critical CO2 heat pump is investigated under different external operation conditions. When the tap-water temperature is low, the charac...
متن کاملTranscritical Co2 Mobile Heat Pump and A/c System Experimental and Model Results
This article presents the results of the experimental runs of a prototype of R744 (CO2) refrigeration system operating in a both air conditioning and heat pump mode when heat rejection is done in supercritical region. The prototype system is sized for a compact car. Data presented are in the limited range of operation. Further optimization and extension of operating range is underway. Test faci...