A blast from the past!: The value of adding single slice magnetic resonance myelography sequence to magnetic resonance imaging of the spine; a flashback to the conventional myelography of the past

نویسندگان

  • P. V. Santosh Rai
  • K. Santosh
  • Shrijeet Chakraborti
  • Shivananda Pai
  • Ishwara Keerthi
  • Muralidhar K. Pai
چکیده

BACKGROUND The study was undertaken to determine whether a single slice magnetic resonance (MR) myelogram sequence improves the interpretation and diagnostic yield for magnetic resonance imaging (MRI) of the spine. METHODS A total of 100 cases with positive findings were retrospectively reviewed. All patients had initial imaging with sagittal T1-weighted (T1-W) and T2-weighted (T2-W) scans, followed by axial T2-W images. Subsequently, a heavily T2-W single slice MR myelogram sequence was acquired in coronal and sagittal planes. The MR myelogram images were evaluated initially by a radiologist, and, further independently reviewed, by a neurologist, neurosurgeon, and spine surgeon. The utility of the MR myelogram in establishing the diagnosis was graded on a 4-point scale. RESULTS Out of 100 cases, 53% showed degenerative spine or disc disease, 14% space occupying lesions, 13%, congenital lesions, 7% infection, and 7% other conditions. The MR myelogram contributed additional information in 50-74% cases. The intraclass correlation coefficient showed overall good agreement between observers in grading the utility of MR myelogram. CONCLUSION Single slice MR myelography is noninvasive avoiding the complications associated with lumbar punctures/intrathecal contrast injections, while image acquisition takes only an added 6-8 s. Although MR myelogram has no value as a stand-alone sequence, its inherent advantage is that it completes the overview of the spinal pathology in entirety, and adds vital three-dimensional information in 50-74% of cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of Magnetic Resonance Imaging in Food Quality Control: A Review

Modern challenges of food science require a new understanding of the determinants of food quality and safety. Application of advanced imaging modalities such as magnetic resonance imaging (MRI) has seen impressive successes and fast growth over the past decade. Since MRI does not have any harmful ionizing radiation, it can be considered as a magnificent tool for the quality control of food prod...

متن کامل

A New Theranostic System Based on Gd2O3 NPs coated Polycyclodextrin Functionalized Glucose for Molecular Magnetic Resonance Imaging (MMRI).

Introduction: Recent advances in nanoscience and biomedicine have attracted tremendous attention over the past decade to design and construct multifunctional nanoparticles that combine targeting, therapeutic, and diagnostic functions with a single platform to overcome the problems of conventional techniques for diagnosis and therapy with minimal toxicity.   Materials ...

متن کامل

Repeatability of Detecting Visual Cortex Activity in Functional Magnetic Resonance Imaging

Introduction As functional magnetic resonance imaging (fMRI) is too expensive and time consuming, its frequent implementation is difficult. The aim of this study is to evaluate repeatability of detecting visual cortex activity in fMRI. Materials and Methods In this study, 15 normal volunteers (10 female, 5 male; Mean age±SD: 24.7±3.8 years) attended. Functional magnetic resonance images were ob...

متن کامل

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2014