Evaluation of tubal microinserts position using 3D ultrasound and pelvic X-ray.

نویسندگان

  • D Moureau
  • N Laurent
  • C Rubod
  • J P Lucot
  • J Salleron
  • N Faye
چکیده

PURPOSE To retrospectively compare three-dimensional ultrasonography (3D-US) and pelvic X-rays to assess the position of tubal sterilization microinserts. MATERIAL AND METHODS Forty-four patients who underwent tubal sterilization with Essure(®) microinserts in our institution were included. The microinserts'position was evaluated three months after the procedure using 3D-US and pelvic X-rays. Placement on 3D-US was binary categorized as correct or incorrect and the distance between the two devices was reported. The orientation and symmetric deployment of the microinserts and the distance between the proximal parts of the two devices was assessed on pelvic X-rays. Performance of 3D-US and pelvic X-ray were compared using Mac Nemar test. Comparison of the distance between the two devices measured on pelvic X-rays and 3D-US was made with the paired Student t test. RESULTS 3D-US images showed microinserts in 93% (41/44). Eighty-six percent (38/44) were correctly positioned on 3D-US and 82% (36/44) on pelvic X-rays. No significant differences between the performances of the two imaging techniques were found. No significant differences for the distance between the two devices measured on pelvic X-ray and 3D-US was found. CONCLUSION 3D-US is a simple, non-ionizing technique, which appears as a promising alternate technique to pelvic X-rays to assess the correct position of Essure(®) microinserts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility of the interpretation of pelvic x-ray 3 months after hysteroscopic sterilization with Essure.

OBJECTIVE To estimate the diagnostic accuracy and the interobserver reproducibility of pelvic x-rays in the diagnosis of successful bilateral sterilization with Essure after a 3-month follow-up period. DESIGN Interobserver study. SETTING Outpatient department of obstetrics and gynecology in a Dutch teaching hospital. PATIENT(S) Patients with successful bilateral Essure placement. INTERV...

متن کامل

Follow-up of successful bilateral placement of Essure microinserts with ultrasound.

OBJECTIVE To evaluate the reliability of pelvic X-ray and transvaginal ultrasound to localize Essure microinserts (Conceptus, San Carlos, California) after successful placement in both fallopian tubes 3 months after placement. DESIGN Prospective, observational study. SETTING Gynecology departments at two teaching hospitals. PATIENT(S) One hundred eighty-two patients who underwent hysteros...

متن کامل

Discordant relationship between Essure microinsert position and tubal occlusion.

Hysteroscopic sterilisation with Essure requires confirmation of tubal occlusion by hysterosalpingogram or microinsert position by transvaginal sonography 3 months after placement before women can rely on the method for pregnancy prevention. A 39-year-old woman underwent hysteroscopic sterilisation via Essure, with successful bilateral tubal occlusion documented on hysterosalpingogram. She had ...

متن کامل

Evaluation of the Prevalence and Utility of Gonad Shielding in Pediatrics Undergoing Pelvic X-Ray

Background: Gonad shielding has been recommended during pelvic x-rays since the 1950s. The popular method of gonad shielding is placement a lead shield in the midline of the pelvis. The aim of this study was to evaluate the prevalence and utility of gonad shielding in pediatrics undergoing pelvic x-rays.Materials and MethodsFollowing study approval, we retrospectively retrieved data from the di...

متن کامل

Essure Surgical Removal and Subsequent Resolution of Chronic Pelvic Pain: A Case Report and Review of the Literature

Background. Hysteroscopic tubal sterilization (Essure) is a minimally invasive option for permanent contraception with high reported rates of patient satisfaction. A small percentage of these women subsequently choose to have the tubal inserts removed due to regret or perceived side effects such as late-onset pelvic pain secondary to placement of the Essure device. Case. A twenty-nine-year-old ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diagnostic and interventional imaging

دوره 96 11  شماره 

صفحات  -

تاریخ انتشار 2015