The Effect of Sagittal Knee Deformity on Preoperative Measurement of Coronal Mechanical Alignment during Total Knee Arthroplasty

نویسندگان

  • Gautam M Shetty
  • Arun Mullaji
  • Ahmed A del Khalifa
  • Abhik Ray
  • Vivek Nikumbha
چکیده

Purpose The purpose of this prospective study was to determine correlation between coronal mechanical alignment measured on preoperative standing full-length radiographs and navigation during total knee arthroplasty (TKA) in the presence of an associated sagittal deformity (hyperextension and flexion deformity). Materials and Methods Coronal mechanical alignment measured on preoperative, standing, full-length, hip-to-ankle anteroposterior radiographs was compared with intraoperative measurements recorded with computer navigation in 200 primary navigated TKAs. Results The mean difference in mechanical alignment between the two techniques was significantly greater (p=0.001) in patients with an associated flexion deformity >10° when compared to knees with associated flexion deformity ≤10°; 48% of knees with a flexion deformity >10° had a difference of ≥3° between the full-length radiograph and navigation alignment measurements. There was a strong correlation between the radiographic and navigation measurement techniques. Conclusions The mean difference in coronal mechanical alignment between the two techniques was significantly higher in patients with an associated flexion deformity >10°. Hence, surgeons should take caution when relying on preoperative full-length radiographs for determining coronal mechanical alignment in patients with an associated flexion deformity >10° where using navigation may be more reliable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty

Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...

متن کامل

The Effect of Total Knee Arthroplasty on Hindfoot Alignment in Patients with Severe Genu Varum and Genu Valgum

Background: The maintenance of deformity in the ankle and hindfoot after correction of knee deformity following kneearthroplasty may cause abnormal tension in the knee and patient dissatisfaction. The aim of this study was to determinethe effect of knee arthroplasty on the hindfoot alignment in patients with severe genu varum and valgum.Methods: A total of 84 patients with pri...

متن کامل

Comparison of total knee arthroplasty using computer-assisted navigation versus conventional guiding systems: a prospective study.

PURPOSE To compare knee alignments in total knee arthroplasty (TKA) using computer-assisted navigation versus conventional guiding systems. METHODS Five men and 49 women aged 49 to 79 years underwent TKA for primary osteoarthritis of the knee with varus deformity. All valgus knees were associated with inflammatory arthritis and thus excluded. Computer-assisted navigation was used for the firs...

متن کامل

Alignment Analyses in the Varus Osteoarthritic Knee Using Computer Navigation.

Osteoarthritic (OA) knees with severe extension varus deformity seem to have correspondingly more severe flexion varus, especially beyond a certain tibiofemoral angle. Clinical measurement of flexion varus and fixed flexion deformity (FFD), which had been difficult to perform because of the spatial alignment of the knee in flexion, was recently made possible with computer navigation. We conduct...

متن کامل

Accuracy of Implant Placement Utilizing Customized Patient Instrumentation in Total Knee Arthroplasty

Customized patient instrumentation (CPI) combines preoperative planning with customized cutting jigs to position and align implants during total knee arthroplasty (TKA). We compared postoperative implant alignment of patients undergoing surgery with CPI to traditional TKA instrumentation for accuracy of implant placement. Twenty-five consecutive TKAs using CPI were analyzed. Preoperative CT sca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2017