Determination of metallic impurities in a silicon wafer by local etching and electrothermal atomic absorption spectrometry.
نویسندگان
چکیده
An etching technique for the determination of the metallic impurities distribution in silicon wafers has been developed. An area of 10 mmphi and 10 microm depth was etched by 100 microL of an etching solution with a HF and HNO3 mixture. The acid matrix was evaporated on the wafer surface by IR lamp illumination and vacuum exhaust. Metallic impurities remaining on the wafer surface were redissolved into the collection solution, which was measured by electrothermal atomic absorption spectrometry (ET-AAS). The recovery invested by local etching/ET-AAS was within 95 - 112% for Fe, Cu and Ni. The detection limit (3sigma) for Fe, Cu and Ni in silicon was 1 x 10(13) atoms/cm3. To confirm the applicability, local etching was applied to evaluate the effects of metallic impurities in a gettering study and the electronic properties of semiconductor devices. It was found that local etching is a useful sample preparation technique for the analysis of metallic impurities in a specific area on a silicon wafer.
منابع مشابه
Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop
The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...
متن کاملCr (VI)/Cr (III) SPECIATION BY IN SITU ELECTRODEPOSITION ONTO TUBE PRIOR TO ELECTROTHERMAL ATOMIC ABSORPTION SPECTROMETRY
متن کامل
Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry
A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...
متن کاملApplication of Ion - Imprinted Polymer Synthesized as New Sorbent for Preconcentration and Separation of Thallium (I) and Its Determination by Electrothermal Atomic Absorption Spectroscopy
At this study, thallium (I) ion-imprinted polymer, as a novel sorbent for Tl (I) and comparison with Tl(III) ion-imprinted polymer has been synthesized. This sorbent for preconcentration and solid-phase extraction of Tl(I) ions from aqueous solutions, used. Through preparing the binary complex of Tl(I) ions with 5, 7-dichloroquinoline-8-ol (DCQ) the particles of thallium (I) Ion-Imprinted P...
متن کاملUtilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples
In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 19 7 شماره
صفحات -
تاریخ انتشار 2003