First steps towards a fast-neutron therapy planning program
نویسندگان
چکیده
BACKGROUND The Monte Carlo code GEANT4 was used to implement first steps towards a treatment planning program for fast-neutron therapy at the FRM II research reactor in Garching, Germany. Depth dose curves were calculated inside a water phantom using measured primary neutron and simulated primary photon spectra and compared with depth dose curves measured earlier. The calculations were performed with GEANT4 in two different ways, simulating a simple box geometry and splitting this box into millions of small voxels (this was done to validate the voxelisation procedure that was also used to voxelise the human body). RESULTS In both cases, the dose distributions were very similar to those measured in the water phantom, up to a depth of 30 cm. In order to model the situation of patients treated at the FRM II MEDAPP therapy beamline for salivary gland tumors, a human voxel phantom was implemented in GEANT4 and irradiated with the implemented MEDAPP neutron and photon spectra. The 3D dose distribution calculated inside the head of the phantom was similar to the depth dose curves in the water phantom, with some differences that are explained by differences in elementary composition. The lateral dose distribution was studied at various depths. The calculated cumulative dose volume histograms for the voxel phantom show the exposure of organs at risk surrounding the tumor. CONCLUSIONS In order to minimize the dose to healthy tissue, a conformal treatment is necessary. This can only be accomplished with the help of an advanced treatment planning system like the one developed here. Although all calculations were done for absorbed dose only, any biological dose weighting can be implemented easily, to take into account the increased radiobiological effectiveness of neutrons compared to photons.
منابع مشابه
Making a novel method to obtain the required irradiation time in fast neutron radiation therapy of liver tissue
During radiotherapy by any radiation, it is always essential to stop absorbing the excess dose by a tissue. To better treat cancerous tissues and to make more precise irradiation for a cancerous tumor, there needs the accurate irradiation time to be estimated. First, the constituent materials of any of the existing organs in abdominal tissue are extracted and defined in the MCNPX code. Then, ev...
متن کاملOptimum neutron energy simulation in treatment of head and neck cancer at different depths in the BNCT method
Introduction: Recently head and neck cancer has pay attention to many researchers. Its therapeutic methods include surgery, chemotherapy, radiotherapy and Boron neutron capture therapy (BNCT). BNCT is better than conventional radiotherapy because it targets the tumor cell. This method involves two steps of infusion of stable 10B and then neutron radiation with a suitable intens...
متن کاملHospital Based Superconducting Cyclotron for Neutron Therapy: Medical Physics Perspective
The neutron therapy facility at the Gershenson Radiation Oncology Center, Harper University Hospital in Detroit has been operational since September 1991. The d(48.5)+Be beam is produced in a gantry mounted superconducting cyclotron designed and built at the National Superconducting Cyclotron Laboratory (NSCL). Measurements were performed in order to obtain the physical characteristics of the n...
متن کاملDesign and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy
Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...
متن کاملAssessment of secondary neutron dose due to dental restorations in head and neck radiation therapy
Introduction: One of scientific concern is increasing of unwanted neutron dose to the patient, in head and neck radiation therapy due to the presence of some isotopes in dental restorations and head of medical linac. The aim of this study is to measure the equivalent dose of thermal and fast neutron due to head of Siemens Primus Linac and a healthy tooth, Amalgam, Ni-Cr alloy a...
متن کامل