Synchronous and baroceptor-sensitive oscillations in skin microcirculation: evidence for central autonomic control.

نویسندگان

  • Luciano Bernardi
  • Daniel Hayoz
  • René Wenzel
  • Claudio Passino
  • Alessandro Calciati
  • Roger Weber
  • Georg Noll
چکیده

To determine whether skin blood flow is local or takes part in general regulatory mechanisms, we recorded laser-Doppler flowmetry (LDF; left and right index fingers), blood pressure, muscle sympathetic nerve activity (MSNA), R-R interval, and respiration in 10 healthy volunteers and 3 subjects after sympathectomy. We evaluated 1) the synchronism of LDF fluctuations in two index fingers, 2) the relationship with autonomically mediated fluctuations in other signals, and 3) the LDF ability to respond to arterial baroreflex stimulation (by neck suction at frequencies from 0.02 to 0.20 Hz), using spectral analysis (autoregressive uni- and bivariate, time-variant algorithms). Synchronous LDF fluctuations were observed in the index fingers of healthy subjects but not in sympathectomized patients. LDF fluctuations were coherent with those obtained for blood pressure, MSNA, and R-R interval. LDF fluctuations were leading blood pressure in the low-frequency (LF; 0.1 Hz) band and lagging in the respiratory, high-frequency (HF; ∼0.25 Hz) band, suggesting passive "downstream" transmission only for HF and "upstream" transmission for LF from the microvessels. LDF fluctuations were responsive to sinusoidal neck suction up to 0.1 Hz, indicating response to sympathetic modulation. Skin blood flow thus reflects modifications determined by autonomic activity, detectable by frequency analysis of spontaneous fluctuations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of an Additive Self-tuning Controller for Static Synchronous Series Compensator for Damping of Sub-synchronous Resonance Oscillations

In this paper, an additive self-tuning (ST) control scheme is presented for a static synchronous series compensator (SSSC) to improve performance of conventional PI control system for damping sub-synchronous resonance (SSR) oscillations. The active and reactve series compensation are provided by a three-level 24-pulse SSSC and fixed capacitor. The proposed ST controller consists of a pole shift...

متن کامل

Nonuniformity of sympathetic nerve activity to the skin and kidney.

NINOMIYA, ISHIO, AYA IRISAWA, AND NAOKO NISIMARU. Nonuniformity of sympathetic nerve activity to the skin and kidney. Am. J. Physiol. 224(Z) : 256-264. 1973.-The effects of baroceptor reflex on the sympathetic nerve activity (SNA) to the skin and kidney were compared in anesthetized cats. Grouped SNA synchronous with cardiac cycle and respiration was not the major pattern in the skin nerve. Wit...

متن کامل

Alleviating the Small-Signal Oscillations of the SMIB Power System with the TLBO–FPSS and SSSC Robust Controller

Power systems are subjected to small–signal oscillations that can be caused by sudden change in the value of large loads. To avoid the dangers of these oscillations, the Power System Stabilizers (PSSs) are used. When the PSSs can not be effective enough, installation of the Thyristor–based compensators to increase the oscillations damping is a suitable method. In this paper, a Static Synchronou...

متن کامل

Sympathetic Skin Response in patients with major depressive disorders

Introduction: Major depressive disorder (MDD) is one of the most prevalent diseases of psychiatry. There is evidence that suggests the autonomic nervous system plays a role in depression. Sympathetic Skin Response (SSR) is used to evaluate the autonomic system. Nerve Conduction Study (NCS) evaluates peripheral thick myelinated fibers. In SSR we evaluate thin unmyelinated fibers. The purpose of ...

متن کامل

Biocompatibility research of a novel pH sensitive ion exchange resin microsphere

The main objective of this study was to investigate biocompatibility and provide in vivo pharmacological and toxicological evidence for further investigation of the possibility of pH sensitive ion exchange resin microsphere for clinical utilizations. Acute toxicity study and general pharmacological studies were conducted on the pH sensitive ion exchange resin microsphere we prepared. The genera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 273 4  شماره 

صفحات  -

تاریخ انتشار 1997