Effect of particle size distribution and chlorophyll content on beam attenuation spectra.

نویسندگان

  • J C Kitchen
  • J R Zaneveld
  • H Pak
چکیده

The relationships between beam attenuation spectra, chlorophyll and pheophytin pigment concentrations, and particle size distributions are examined for a coastal region (Monterey Bay area) believed to have negligible concentrations of terrestrially derived dissolved organic compounds (during May 1977) but large quantities of phytoplankton and resuspended sediments. It was found that the slope of the beam attenuation spectra increases when the hyperbolic slope of the size distribution increases. The magnitude of this increase in slope was consistent with calculations based on a range of particle diameters from 0.5 to 30 microm, so that it would be possible to predict the slope of the particle size distribution if the slope of the beam attenuation spectra is known. The ratio of chlorophyll and pheophytin pigments to suspended volume concentrations affected the beam attenuation spectra to a lesser degree and in a more complex manner. Because of the strong effect of slope, it was concluded that the chlorophyll and pheophytin pigment content of suspended particles could not be efficiently predicted by means of beam attenuation measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Towards Cost-Effective Operational Monitoring Systems for Complex Waters: Analyzing Small-Scale Coastal Processes with Optical Transmissometry

The detection and prediction of changes in coastal ecosystems require a better understanding of the complex physical, chemical and biological interactions, which involves that observations should be performed continuously. For this reason, there is an increasing demand for small, simple and cost-effective in situ sensors to analyze complex coastal waters at a broad range of scales. In this cont...

متن کامل

Spectral particulate attenuation and particle size distribution in the bottom boundary layer of a continental shelf

Spectral attenuation and absorption coefficients of particulate matter and colocated hydrographic measurements were obtained in the Mid-Atlantic Bight during the fall of 1996 and the spring of 1997 as part of the Coastal Mixing and Optics experiment. Within the bottom boundary layer (BBL) the magnitude of the beam attenuation decreased and its spectral shape became steeper with distance from th...

متن کامل

Monte Carlo calculation of shielding properties of newly developed heavy concretes for megavoltage photon beam spectra used in radiation therapy

Introduction: Globally, the need for radiotherapy as a part of cancer management increases every year. Thus, the shielding for megavoltage radiotherapy rooms is of great importance. Materials and Methods: In the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using Monte Carlo method. The linear attenuation coefficient and t...

متن کامل

An Update of Couch Effect on the Attenuation of Megavoltage Radiotherapy Beam and the Variation of Absorbed Dose in the Build-up Region

Purpose: Fiber carbon is the most common material used in treating couch as it causes less beam attenuation than other materials. Beam attenuation replaces build-up region, reduces skin-sparing effect and causes target volume under dosage. In this study, we aimed to evaluate beam attenuation and variation of build-up region in 550 TxT radiotherapy couch.Materials and Methods: In this study, we ...

متن کامل

Investigations of parameters affecting the photon energy spectra of an 18 MV Varian 2100C/D linear accelerator

Radiotherapy using linear accelerators is known as an effective modality for cancer treatment. The photons energy of treatment beams significantly affect the dose distribution. Therefore, it is important to accurately evaluate the photon energy spectra. In this study, MCNPX Monte Carlo code (version 2.6.0) was used to simulate an 18 MV photon beam of a Varian 2100C/D linear accelerator. By matc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 21 21  شماره 

صفحات  -

تاریخ انتشار 1982