Comparison With Positron Emission Tomography and Quantitative Arteriography

نویسنده

  • Eugenio Picano
چکیده

Background The aim of this study was to compare the results of dipyridamole-echocardiography test (DET: twodimensional echo monitoring during dipyridamole infusion up to 0.84 mg/kg over a period of 10 minutes) with both anatomic and physiological parameters of coronary artery disease severity, assessed by computer-assisted quantitative coronary arteriography, and regional coronary flow reserve, measured by [13N]ammonia (13NH3) and dynamic positron emission tomography (PET), respectively. Methods and Results We studied 31 patients with a history of chest pain and neither previous myocardial infarction nor resting wall motion abnormalities. Eighteen patients had single-vessel disease (>50% stenosis of one major coronary vessel), and 13 had normal coronary arteries. The criterion for DET positivity was the appearance of a new transient regional wall motion abnormality. In patients with a positive DET, two parameters were evaluated: the dipyridamole time (ie, the time from the beginning of drug infusion to the development of obvious dyssynergy) and the wall motion score index (WMSI, a semiquantitative integrated estimation of extent and severity of the stress-induced dyssynergy). WMSI was derived by summation of individual segment scores divided by the number of segments interpreted. Quantification of regional myocardial blood flow was obtained by PET measurements of 13NTH3 arterial input function and left ventricular myocardial tissue concentration both at control and after dipyridamole (0.56 mg/kg over 4 minutes). Maximal regional blood flow

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lesions by Dipyridamole Echocardiography Comparison With Positron Emission Tomography and Quantitative Arteriography

Background The aim of this study was to compare the results of dipyridamole-echocardiography test (DET: twodimensional echo monitoring during dipyridamole infusion up to 0.84 mg/kg over a period of 10 minutes) with both anatomic and physiological parameters of coronary artery disease severity, assessed by computer-assisted quantitative coronary arteriography, and regional coronary flow reserve,...

متن کامل

Assessment of coronary artery disease severity by positron emission tomography. Comparison with quantitative arteriography in 193 patients.

To assess the accuracy of positron emission tomography (PET) for evaluation of coronary artery disease (CAD), cardiac PET perfusion images were obtained at rest and with dipyridamole-handgrip stress in 193 patients undergoing coronary arteriography. PET images were reviewed by two independent readers blinded to clinical data. Subjective defect severity scores were assigned to each myocardial re...

متن کامل

Detection of Alzheimer\\\\\\\'s Disease using Multitracer Positron Emission Tomography Imaging

Alzheimer's disease is characterized by impaired glucose metabolism and demonstration of amyloid plaques. Individual positron emission tomography tracers may reveal specific signs of pathology that is not readily apparent on inspection of another one. Combination of multitracer positron emission tomography imaging  yields promising results. In this paper, 57 Alzheimer's disease neuroimaging ini...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

An overview on Ga-68 radiopharmaceuticals for positron emission tomography applications

Gallium-68 a positron emitter radionuclide, with great impact on the nuclear medicine, has been widely used in positron emission tomography (PET) diagnosis of various malignancies in humans during more recent years especially in neuroendocrine tumors (NETs). The vast number of 68Ge/68Ga related generator productions, targeting molecule design (proteins, antibody fragments,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005