Digital Radiography Using Digital Detector Arrays Fulfills Critical Applications for Offshore Pipelines

نویسندگان

  • Edson Vasques Moreira
  • José Maurício Barbosa Rabello
  • Marcelo dos Santos Pereira
  • Ricardo Tadeu Lopes
  • Uwe Zscherpel
چکیده

1Nondestructive Testing Laboratory of TenarisConfab, 475 Av. Dr. Gastão Vidigal Neto, Pindamonhangaba, 12414-900, SP, Brazil 2Universidade Estadual Paulista (UNESP)-FEG, 333 Av. Doutor Ariberto Pereira da Cunha, Guaratinguetá, 12516-410, SP, Brazil 3 Petrobras/Engenharia/SL/SEQUI/CI, Km 143 Rodovia Presidente Dutra, São José dos Campos, 12220-840, SP, Brazil 4Department of Materials and Technology, UNESP, FEG, 333 Av. Doutor Ariberto Pereira da Cunha, Guaratinguetá, 12516-410, SP, Brazil 5Nuclear Instrumentation Laboratory, COPPE, Universidade Federa do Rio de Janeiro, Rio de Janeiro, Brazil 6BAM, Federal Institute for Materials Research and Testing, Radiological Methods, 87 Unter den Eichen, 12205, Berlin, Germany

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effective Dose Evaluation of Critical Organes in Digital Radiography Exames

Background and Aim: Due to the increasing number of radiographic tests, TLD dosimeters can be used to measure the effective dose of critical organs in various radiographic tests. In this research, the progression of analogue to digital radiology devices, which facilitates and accelerates the performance of radiographs, especially emergency patients, was investigated, and then the effective dose...

متن کامل

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

Recent Trends in Digital Industrial Radiology

New digital detectors were developed for medical applications, which have the potential to substitute the X-ray film and revolutionise the radiological technique. Flat panels and imaging plates allow a fast detection of radiographs in a shorter time and with higher dynamic than film applications. The properties of these detectors can be controlled by electronics and exposure conditions. New nam...

متن کامل

Replacement of Film Radiography by Digital Techniques and Enhancement of Image Quality

New digital detectors were developed for medical applications, which have the potential to substitute the X-ray film. Digital Detector Arrays (DDA: Flat Panel Detectors, Line Detectors) and Imaging Plates (Computed Radiography, CR) allow a fast acquisition of radiographic images with higher dynamic than film. Especially DDA’s allow a radiographic inspection with considerable higher image qualit...

متن کامل

Comparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects

Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects.  Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • EURASIP J. Adv. Sig. Proc.

دوره 2010  شماره 

صفحات  -

تاریخ انتشار 2010