The deflation limb of the pressure-volume relationship in infants during high-frequency ventilation.

نویسندگان

  • David G Tingay
  • John F Mills
  • Colin J Morley
  • Anastasia Pellicano
  • Peter A Dargaville
چکیده

RATIONALE The importance of applying high-frequency oscillatory ventilation with a high lung volume strategy in infants is well established. Currently, a lack of reliable methods for assessing lung volume limits clinicians' ability to achieve the optimum volume range. OBJECTIVES To map the pressure-volume relationship of the lung during high-frequency oscillatory ventilation in infants, to determine at what point ventilation is being applied clinically, and to describe the relationship between airway pressure, lung volume, and oxygenation. METHODS In 12 infants, a partial inflation limb and the deflation limb of the pressure-volume relationship were mapped using a quasi-static lung volume optimization maneuver. This involved stepwise airway pressure increments to total lung capacity, followed by decrements until the closing pressure of the lung was identified. MEASUREMENTS AND MAIN RESULTS Lung volume and oxygen saturation were recorded at each airway pressure. Lung volume was measured using respiratory inductive plethysmography. A distinct deflation limb could be mapped in each infant. Overall, oxygenation and lung volume were improved by applying ventilation on the deflation limb. Maximal lung volume and oxygenation occurred on the deflation limb at a mean airway pressure of 3 and 5 cm H(2)O below the airway pressure approximating total lung capacity, respectively. CONCLUSIONS Using current ventilation strategies, all infants were being ventilated near the inflation limb. It is possible to delineate the deflation limb in infants receiving high-frequency oscillatory ventilation; in doing so, greater lung volume and oxygenation can be achieved, often at lower airway pressures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changes in lung volume and ventilation during surfactant treatment in ventilated preterm infants.

RATIONALE The immediate and regional effects of exogenous surfactant in open lung high-frequency oscillatory ventilated (HFOV) preterm infants are unknown. OBJECTIVES To assess regional changes in lung volume, mechanics, and ventilation during and after surfactant administration in HFOV preterm infants with respiratory distress syndrome (RDS). METHODS Using electrical impedance tomography, ...

متن کامل

Setting mean airway pressure during high-frequency oscillatory ventilation according to the static pressure--volume curve in surfactant-deficient lung injury: a computed tomography study.

BACKGROUND Numerous studies suggest setting positive end-expiratory pressure during conventional ventilation according to the static pressure-volume (P-V) curve, whereas data on how to adjust mean airway pressure (P(aw)) during high-frequency oscillatory ventilation (HFOV) are still scarce. The aims of the current study were to (1) examine the respiratory and hemodynamic effects of setting P(aw...

متن کامل

Optimal mean airway pressure during high-frequency oscillation: predicted by the pressure-volume curve.

BACKGROUND A number of groups have recommended setting positive end-expiratory pressure during conventional mechanical ventilation in adults at 2 cm H2O above the lower corner pressure (P(CL)) of the inspiratory pressure-volume (P-V) curve of the respiratory system. No equivalent recommendations for the setting of the mean airway pressure (Paw) during high-frequency oscillation (HFO) exist. The...

متن کامل

Estimating lung volume during high frequency ventilation

The primary goals of lung ventilation are to bring oxygen into the alveoli from where it can enter the blood, and to eliminate carbon dioxide dissolved in the blood. Since CO2 is much more soluble in blood than oxygen, O2 transport is diffusion-limited and a large alveolar surface area is the primary factor controlling its delivery. CO2 transport is flow-limited, so that efficient gas transport...

متن کامل

Volume-guaranteed Ventilation Versus Pressure-controlled Ventilation in Preterm Infants with Respiratory Distress Syndrome: A Randomized Controlled Trial

Background: This study was targeted toward comparing volume-guaranteed (VG) ventilation with conventional pressure-controlled (PC) ventilation in preterm infants with respiratory distress syndrome (RDS) in terms of the facilitation of weaning and extubation and occurrence of complications, such as pneumothorax, intraventricular hemorrhage (IVH), retinopathy of prematur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of respiratory and critical care medicine

دوره 173 4  شماره 

صفحات  -

تاریخ انتشار 2006