Comparative evaluation of 64-slice CT angiography and digital subtraction angiography in assessing the cervicocranial vasculature
نویسندگان
چکیده
BACKGROUND Noninvasive 64-slice computed tomography angiography (64-MSCTA) closely approximates conventional catheter angiography (DSA) in terms of detail resolution. OBJECTIVE Retrospective evaluation of cervicocranial (cc) 64-MSCTA in comparison with DSA in patients with presumptive cc vascular disorders. MATERIAL AND METHODS Twenty-four 64-MSCTA studies (32 mm detector width, slice thickness 0.5 mm, 120 kv, 150 mAs, pitch 0.75) of patients with presumptive cc vascular pathology (13 men, 11 women, mean age 38.3 +/- 11.3 yrs, range 19-54 yrs) were assessed in comparison with DSA studies without abnormal findings in age-matched patients (11 men, 13 women, mean age 39.7 +/- 11.9 yrs, range 18-54 yrs). Study readings were performed in a blinded manner by two neuroradiologists with respect to image quality and assessibility of various cc vascular segments by using a five-point scale. Radiation exposure was calculated for 64-MSCTA. RESULTS Each reader assessed 384/528 different vessel segments (64-MSCTA/DSA). Superior image quality was attributed to DSA with respect to the C1 ICA-C6 ICA, A3 ACA, and P3 PCA segments as well the AICA and SCA. 64-MSCTA was scored superior for C7 ICA and V4 VA segments. A significantly increased number ofnonassessable V2- and V3 VA segments in DSA studies was noted. The effective dose for 64-MSCTA amounted to 2.2 mSv. CONCLUSIONS 64-MSCTA provides near-equivalent diagnostic information of the cc vasculature as compared with DSA. According to our results, DSA should be considered primarily when peripheral vessels (A3/P3) or ICA segments close to the skull base (C2-5) are of interest, such as in primary angiitis or stenoocclusive ICA disease, respectively.
منابع مشابه
مقایسه یافتههای آنژیوگرافی عروق کلیوی به روش توموگرافی کامپیوتری چندلایه با یافتههای جراحی در افراد زنده دهنده کلیه
Background: In kidney transplantation decision about the proper kidney donation is different between surgeons, but simple vasculature anatomy and a kidney without abnormalities are the most important reasons of choosing a kidney. Therefore complete assessment of renal vessels of a live donor with noninvasive techniques is a necessity for nephrectomy. For delineation of the kidney vasculature...
متن کاملApplication of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study
Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...
متن کاملAn evaluation of the arterial occlusions in peripheral arterial disease by 64-detector multi-slice CT angiography: DSA correlation
Objective: Evaluation of peripheral arterial disease with 64-detector multi-slice CT angiography (MDCTA) and comparison of the results with the results of digital subtraction angiography (DSA), a standard reference. Materials and Method: The written informed consent of the patients and ethics committee approval were obtained. The retrospective study group consisted of 28 patients with a diagnos...
متن کاملEvaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences
OBJECTIVE To explore the usefulness of 320-slice CT angiography (CTA) for evaluating the course of the anterior ethmoidal artery (AEA) and its relationship with adjacent structures by using three-dimensional (3D) spin digital subtraction angiography (DSA) as standard reference. MATERIALS AND METHODS From December 2008 to December 2010, 32 patients with cerebrovascular disease, who underwent b...
متن کاملComparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism
Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vascular Health and Risk Management
دوره 4 شماره
صفحات -
تاریخ انتشار 2008