Variation of rotation moment arms with hip flexion.

نویسندگان

  • S L Delp
  • W E Hess
  • D S Hungerford
  • L C Jones
چکیده

Excessive flexion and internal rotation of the hip is a common gait abnormality among individuals with cerebral palsy. The purpose of this study was to examine the influence of hip flexion on the rotational moment arms of the hip muscles. We hypothesized that flexion of the hip would increase internal rotation moment arms and decrease external rotation moment arms of the primary hip rotators. To test this hypothesis we measured rotational moment arms of the gluteus maximus (six compartments), gluteus medius (four compartments), gluteus minimus (three compartments) iliopsoas, piriformis, quadratus femoris, obturator internus, and obturator externus. Moment arms were measured at hip flexion angles of 0, 20, 45, 60, and 90 degrees in four cadavers. A three-dimensional computer model of the hip muscles was developed and compared to the experimental measurements. The experimental results and the computer model showed that the internal rotation moment arms of some muscles increase with flexion; the external rotation moment arms of other muscles decrease, and some muscles switch from external rotation to internal rotation as the hip is flexed. This trend toward internal rotation with hip flexion was apparent in 15 of the 18 muscle compartments we examined, suggesting that excessive hip flexion may exacerbate internal rotation of the hip. The gluteus maximus was found to have a large capacity for external rotation. Enhancing the activation of the gluteus maximus, a muscle that is frequently underactive in persons with cerebral palsy, may help correct excessive flexion and internal rotation of the hip.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of muscle moment arms estimated from MRI-based musculoskeletal models of the lower extremity.

OBJECTIVE Biomechanical models that compute the lengths and moment arms of soft tissues are broadly applicable to the treatment of movement abnormalities and the planning of orthopaedic surgical procedures. The goals of this study were to: (i) develop methods to construct subject-specific biomechanical models from magnetic resonance (MR) images, (ii) create models of three lower-extremity cadav...

متن کامل

Effects of stimulated hip extension moment and position on upper-limb support forces during FNS-induced standing--a technical note.

This study explores the effects of active hip extension moment produced by electrical stimulation on the support forces the arms must exert through an assistive device during quiet erect standing with functional neuromuscular stimulation (FNS) in individuals with spinal cord injuries (SCI). A static sagittal plane biomechanical model of human standing was developed to predict the effects of sti...

متن کامل

Variation of muscle moment arms with elbow and forearm position.

We hypothesized that the moment arms of muscles crossing the elbow vary substantially with forearm and elbow position and that these variations could be represented using a three-dimensional computer model. Flexion/extension and pronation/supination moment arms of the brachioradialis, biceps, brachialis, pronator teres, and triceps were calculated from measurements of tendon displacement and jo...

متن کامل

Wrapping Surfaces to Control Moment Arm Lengths during a Squat Task

Simulation of high flexion tasks such as squatting is hindered through invalid moment length estimation when using generic musculoskeletal (MSK) models. The purpose of this study was to examine the effect of wrapping surface (WS) at the knee and hip joints on the muscle moment arms calculated using a MSK model during squatting tasks. A generic full body model was modified by (1) increasing knee...

متن کامل

Rotational moment arms of the medial hamstrings and adductors vary with femoral geometry and limb position: implications for the treatment of internally rotated gait.

Persons with cerebral palsy frequently walk with a crouched, internally rotated gait. Spastic medial hamstrings or adductors are presumed to contribute to excessive hip internal rotation in some patients; however, the capacity of these muscles to produce internal rotation has not been adequately investigated. The purpose of this study was to determine the hip rotation moment arms of the medial ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 32 5  شماره 

صفحات  -

تاریخ انتشار 1999