BACKGROUND AND OBJECTIVE The Intubating Laryngeal Mask Airway FastrachTM (ILMA) has been used with success in difficult intubation cases. The purpose of this study is to evaluate the effect of mouth opening, Mallampati classification, thyromental distance and Cormack-Lehane Grade, on the ease of ILMA use. METHODS Eighty one patients ASA I-II, were assessed preoperatively for mouth opening, Mallampati classification and thyromental distance. After induction with propofol and rocuronium, the first investigator recorded Cormack-Lehane Grade by direct laryngoscopy. Subsequently an appropriate size ILMAwas inserted by the second investigator and correct placement was confirmed by adequate ventilation and normal capnogram. A maximum of three ILMA insertion attempts were allowed and the number was recorded. Then blind intubation was attempted and classified as follows, according to Intubation Difficulty Grade (IDG): IDG-1: intubation succeeded: at first attempt requiring no or minor ILMA manipulations. IDG-2: intubation succeeded at second attempt requiring major ILMA manipulations or size change. IDG-3: intubation failed after the second attempt or oesophageal intubation occurred at either attempt. In failure of the technique direct laryngoscopy was the alternative approach. RESULTS Success rates in insertion of ILMA and in blind intubation were 100% and 92.6% respectively. No difference was found between Cormack-Lehane Grade I-II and II-IV or Mallampati classification and number of ILMA insertion attempts or IDG. There was also no correlation between mouth opening, or thyromental distance and number of ILMA insertion attempts or IDG. It is concluded that easiness of ILMA use is irrelevant to mouth opening, thyromental distance, Mallampati classification or Cormack-Lehane Grade.
منابع مشابه
Case Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
Introduction: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication. Case Report...
متن کاملComparison of the effect of thiopental sodium-midazolam combination on the hemodynamic response between tracheal intubation and laryngeal mask airway insertion: A clinical trial study
Background and Aim: The purpose of this study was to compare the effect of thiopental sodium-midazolam combination on the stress response and hemodynamic changes between tracheal intubation and laryngeal mask airway insertion during airway management. Materials and Methods: In this clinical trial study, 70 patients ASA 1, 2 candidates for elective surgery were randomly divided into two groups o...
متن کاملLimitation of Laryngeal Mask Airway Usage in Open-Neck Procedure
I read the manuscript entitled “Case Report of An Open Neck Procedure Complication Associated with Laryngeal Mask Airway Use” by Subramaniam T et al. This is a valuable manuscript describing iatrogenic complications during level-2 cervical lymph node biopsy, in which the airway is managed with laryngeal mask airway (LMA). During the procedure, the surgeon realized that the mass was actually the...
متن کاملمقایسه اثر استفاده از ماسک حنجره (Laryngeal mask airway) و لوله کافدار حلقی (Cuffed pharyngeal tube) در بروز گلودرد پس از بیهوشی عمومی در بزرگسالان
Post-operative sore throat is one of the most common complications and complaints of patients after general anesthesia especially in operations that need endotracheal intubations. Its causes are: size of endotracheal tube and type of its cuff, inadequate airway humidification, trauma during intubation and suctioning, high flow of inspiratory gases, surgical manipulation of airway and adjacent o...
متن کاملHemodynamic responses to insertion of the laryngeal mask airway versus Combitube
Introduction: One of the most common problems during laryngoscopy involves sympathetic system stimulation and the subsequent hemodynamic changes. It is a key measure to maintain the hemodynamic stability of patients with cardiovascular diseases during induction of anesthesia. This study attempted to compare the hemodynamic effects of laryngeal mask airway and combitube. Methods: This prospec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Middle East journal of anaesthesiology
دوره 20 4 شماره
صفحات -
تاریخ انتشار 2010