Lung assist device: development of microfluidic oxygenators for preterm infants with respiratory failure.

نویسندگان

  • Wen-I Wu
  • Niels Rochow
  • Emily Chan
  • Gerhard Fusch
  • Asmaa Manan
  • Dipen Nagpal
  • P Ravi Selvaganapathy
  • Christoph Fusch
چکیده

This paper reports the development of microfluidic oxygenator (MFO) units designed for a lung assist device (LAD) for newborn infants. This device will be connected to the umbilical vessels like the natural placenta and provide gas exchange. The extracorporeal blood flow is only driven by the pressure difference between the umbilical artery and vein without the use of external pumps. The LAD is designed for use in ambient air (~21% of 760 mmHg). The main focus of this paper is the presentation of the development of the MFO units testing various membrane materials with human blood to enhance gas exchange and in the design of fluidic inlets to lower the pressure drop across the oxygenator. Four different membranes, including thin film PDMS, porous PDMS, and two different pore size porous polycarbonate membranes are compared in this study. Among them, the microfluidic oxygenator with porous PDMS membrane has the highest gas exchange rate of 1.46 μL min(-1) cm(2) for oxygen and 5.27 μL min(-1) cm(2) for carbon dioxide and performs better than a commercial hollow fiber-based oxygenator by 367 and 233%, respectively. A new tapered inlet configuration was designed to reduce the pressure drop across the oxygenator and showed a further 57% improvement over the traditional perpendicular inlet configuration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artificial placenta--lung assist devices for term and preterm newborns with respiratory failure.

Respiratory insufficiency is a major cause of neonatal mortality and long-term morbidity, especially in very low birth weight infants. Today, non-invasive and mechanical ventilation are commonly accepted procedures to provide respiratory support to newborns, but they can reach their limit of efficacy. To overcome this technological plateau and further reduce mortality rates, the technology of a...

متن کامل

Effective Factors of INSURE Method Failure in Treatment of Respiratory Distress Syndrome in Preterm Infants

Background INtubate-SURfactant-Extubate (INSURE) method is one of the effective methods in treatment of infants with respiratory distress syndrome (RDS). This study was performed to predict risk factors for the failure of  INSURE method in treatment of RDS in preterm infants. Materials and Methods: In this cross-sectional study, 192 infants who born between July 2011 and April 2016 at women and...

متن کامل

Could mean platelet volume predict developing of bronchopulmonary dysplasia in preterm infants with respiratory distress syndrome?

Introduction: some studies have suggested correlation between MPV index and inflammatory diseases such as rheumatoid arthritis in adults. Though bronchopulmonary dysplasia is also an inflammatory disease which develops in preterm neonates with Respiratory distress syndrome, we decided to study the possible correlation between the mean platelet volume (MPV) and the occurrence of bronchopulmonary...

متن کامل

An integrated array of microfluidic oxygenators as a neonatal lung assist device: in vitro characterization and in vivo demonstration.

A miniaturized oxygenator device that is perfused like an artificial placenta via the umbilical vessels may have significant potential to save the lives of newborns with respiratory insufficiency. Recently we presented the concept of an integrated modular lung assist device (LAD) that consists of stacked microfluidic single oxygenator units (SOUs) and demonstrated the technical details and oper...

متن کامل

Lung assist device technology with physiologic blood flow developed on a tissue engineered scaffold platform.

There is no technology available to support failing lung function for patients outside the hospital. An implantable lung assist device would augment lung function as a bridge to transplant or possible destination therapy. Utilizing biomimetic design principles, a microfluidic vascular network was developed for blood inflow from the pulmonary artery and blood return to the left atrium. Computati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 13 13  شماره 

صفحات  -

تاریخ انتشار 2013