Passivation Characteristics of Alloy Corrosion-Resistant Steel Cr10Mo1 in Simulating Concrete Pore Solutions: Combination Effects of pH and Chloride
نویسندگان
چکیده
The electrochemical behaviour for passivation of new alloy corrosion-resistant steel Cr10Mo1 immersed in alkaline solutions with different pH values (13.3, 12.0, 10.5, and 9.0) and chloride contents (0.2 M and 1.0 M), was investigated by various electrochemical techniques: linear polarization resistance, electrochemical impedance spectroscopy and capacitance measurements. The chemical composition and structure of passive films were determined by XPS. The morphological features and surface composition of the immersed steel were evaluated by SEM together with EDS chemical analysis. The results evidence that pH plays an important role in the passivation of the corrosion-resistant steel and the effect is highly dependent upon the chloride contents. In solutions with low chloride (0.2 M), the corrosion-resistant steel has notably enhanced passivity with pH falling from 13.3 to 9.0, but does conversely when in presence of high chloride (1.0 M). The passive film on the corrosion-resistant steel presents a bilayer structure: an outer layer enriched in Fe oxides and hydroxides, and an inner layer, rich in Cr species. The film composition varies with pH values and chloride contents. As the pH drops, more Cr oxides are enriched in the film while Fe oxides gradually decompose. Increasing chloride promotes Cr oxides and Fe oxides to transform into their hydroxides with little protection, and this is more significant at lower pH (10.5 and 9.0). These changes annotate passivation characteristics of the corrosion-resistant steel in the solutions of different electrolyte.
منابع مشابه
Electrochemical and passivation behavior investigation of ferritic stainless steel in simulated concrete pore media
The applications of stainless steel are one of the most reliable solutions in concrete structures to reduce chloride-induced corrosion problems and increase the structures service life, however, due to high prices of nickel, especially in many civil engineering projects, the austenitic stainless steel is replaced by the ferritic stainless steels. Compared with austenite stainless steel, the fer...
متن کاملPitting Corrosion Behaviour of New Corrosion-Resistant Reinforcement Bars in Chloride-Containing Concrete Pore Solution
In this study, the pitting behaviour of a new corrosion-resistant alloy steel (CR) is compared to that of low-carbon steel (LC) in a simulated concrete pore solution with a chloride concentration of 5 mol/L. The electrochemical behaviour of the bars was characterised using linear polarisation resistance (LPR) and electrochemical impedance spectroscopy (EIS). The pitting profiles were detected b...
متن کاملThe Passive Film Growth Mechanism of New Corrosion-Resistant Steel Rebar in Simulated Concrete Pore Solution: Nanometer Structure and Electrochemical Study
An elaborative study was carried out on the growth mechanism and properties of the passive film for a new kind of alloyed corrosion-resistant steel (CR steel). The passive film naturally formed in simulated concrete pore solutions (pH = 13.3). The corrosion resistance was evaluated by various methods including open circuit potential (OCP), linear polarization resistance (LPR) measurements, and ...
متن کاملINVESTIGATION ON THE MIXTURE OF CALCIUM AND AMMONIUM NITRATES AS STEEL CORROSION INHIBITOR IN SIMULATED CONCRETE PORE SOLUTION
Abstract: Despite having a number of advantages, reinforced concrete can suffer rebar corrosion in high–chloride media, resulting in failure of reinforced concrete structures. In this research the corrosion inhibition capability of the mixture of calcium and ammonium nitrate of steel rebar corrosion was investigated in the simulated concrete pore solution. Cyclic polarization and Electroche...
متن کاملCorrosion Performance of Stainless Steel Clad Rebar in Simulated Pore Water and Concrete
The corrosion performance of stainless steel clad reinforcing bar (SCR) was investigated. Corrosion potential of SCR in various alkaline media as a function of time was measured periodically and corrosion rates were estimated using Electrochemical Impedance Spectroscopy (EIS). At room temperature, SCR without cladding breaks was free of corrosion for up to one year in all the testing conditions...
متن کامل