Evaluation of the ESP Culture System II for recovery of mycobacteria from blood specimens collected in isolator tubes.

نویسندگان

  • C A Tholcken
  • S Huang
  • G L Woods
چکیده

The reliability of the ESP Culture System II (ESP II; AccuMed International, Westlake, Ohio), a continuously monitoring, nonradiometric mycobacterial culture system, for recovery of mycobacteria from sediments of blood collected in an Isolator tube was evaluated by comparing its performance to inoculation of the sediment onto Middlebrook 7H11/7H11 selective biplates. Of 1,704 blood specimens, 73 (4.3%) were positive for mycobacteria (68 Mycobacterium avium complex and 5 M. tuberculosis). Fifty-three specimens were positive by both methods; 13 were positive by ESP II only, and 7 were positive by Middlebrook agar only (chi square = 1.8; P > 0.05). The mean times to positivity were 15.6 days for ESP II and 19.0 days for Middlebrook agar (P < 0.01). The time to detection was the same for 13 specimens; ESP II was positive first for 33, and agar plates were positive first for 7. ESP II allowed recovery of more mycobacteria (90.4% of all isolates versus 82.2% for Middlebrook agar) from sediments of blood specimens collected in Isolator tubes, and it provided significantly faster detection than did Middlebrook plates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of BACTEC MYCO/F lytic medium for recovery of mycobacteria and fungi from blood.

The reliability of MYCO/F Lytic medium in the BACTEC 9240 blood culture system was evaluated by comparing its performance to that of the Isolator system for the recovery of fungi and to that of the ESP II system for the recovery of mycobacteria. Of 717 specimens of blood cultured for fungi, 24 were positive; 12 samples were positive with both systems, 7 samples were positive with the Isolator s...

متن کامل

Comparison of the BACTEC MGIT 960 and ESP culture system II for growth and detection of mycobacteria.

The performances of two continuously monitoring mycobacterial culture systems-ESP Culture System II (ESP II; Trek Diagnostics, Inc. , Westlake, Ohio) and BACTEC MGIT 960 (BD Biosciences, Sparks, Md. )-were compared. In addition to both liquid media, all specimens were plated onto Middlebrook 7H11/7H11 selective agar. A total of 3, 151 specimens of all types (56.3% were respiratory specimens) we...

متن کامل

Multicenter comparison of ESP Culture System II with BACTEC 460TB and with Lowenstein-Jensen medium for recovery of mycobacteria from different clinical specimens, including blood.

The recently developed ESP Culture System II (AccuMed, Chicago, Ill.) was compared with radiometric BACTEC 460TB (Becton Dickinson, Towson, Md.) and with Lowenstein-Jensen medium for recovery of mycobacteria from over 2,500 clinical specimens both of respiratory and nonrespiratory origin, including blood. The majority of the 219 mycobacterial isolates (129) belonged to the Mycobacterium tubercu...

متن کامل

Evaluation of BACTEC MYCO/F Lytic medium for recovery of mycobacteria, fungi, and bacteria from blood.

MYCO/F Lytic medium (MFL), a liquid medium developed for use with the BACTEC 9240 blood culture system, was compared to the Isolator system (IS) for the recovery of fungi and to the BACTEC 13A medium for the recovery of mycobacteria. Recovery of bacteria was compared to routine BACTEC Plus Aerobic/F (AF) blood cultures. Microbial growth was detected in 203 (17%) of 1,166 blood cultures. Fifty-s...

متن کامل

Use of the Isolator 1.5 microbial tube for detection of Brucella melitensis in synovial fluid.

Isolation of brucellae from blood and other normally sterile body fluids or tissues remains the only irrefutable evidence for the disease, but detection of the organism in clinical specimens is frequently hampered by the low sensitivity of routine culture methods. Because brucellae have the ability to survive and multiply within phagocytic cells, we speculated that phagocytosis of the organism ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 35 10  شماره 

صفحات  -

تاریخ انتشار 1997