Slotted end-ring volume coil for small animal Magnetic Resonance Imaging at 7T

نویسندگان

  • O. R. Marrufo
  • S. E. Solis
  • S. S. Hidalgo
  • A. O. Rodriguez
چکیده

Introduction. The development of transceiver volume coils for high field MRI is still a very dynamic field of investigation and development. A volume coil based on the high frequency cavity resonator [1] is presented in this paper for whole-body MRI of rodents at 7 Tesla (proton frequency: 299.47 MHz). This coil design has been previously tested on phantoms at 170 MHz (4T for protons) with standard spin echo sequences [2]. The encouraging results obtained with this coil design motivated us to develop a whole-body coil for rodents (in a) at higher magnetic field MRI. The coil design with slotted end-rings presented here is a variant of the coil above and was developed to work at 300 MHz. This coil design operates in the transceiver mode and was designed for small biological samples. A popular birdcage coil was constructed in order to compare their performances. Phantom and rat images proved the viability of this coil design for high field MRI applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Asymmetric Birdcage Coil for Small-animal MR Imaging at 7T

The birdcage (BC) coil is currently being utilized for uniform radiofrequency (RF) transmit/receive (Tx/Rx) or Tx-only configuration in many magnetic resonance (MR) imaging applications, but insufficient magnetic flux (|B1|) density and their non-uniform distribution still exists in high-field (HF) environments. We demonstrate that the asymmetric birdcage (ABC) transmit/receive (Tx/Rx) volume c...

متن کامل

Magnetron volume coil for Magnetic Resonance Imaging of rodents

Introduction. There is still a great interest to develop volume coils for small-animal MRI. A transceiver volume coil with slotted end-rings and similar to the standard birdcage is proposed in this work. This coil design resembles Mansfield ́s cavity resonator [1]. Unlike the traditional birdcage coil, our coil design was formed with two slotted surface coils [2] connected via rungs like the tra...

متن کامل

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

Slotted surface coil for magnetic resonance imaging at 4T

Synopsis. A slotted surface coil, inspired on the cavity magnetron was developed for magnetic resonance imaging (MRI) at 4T. Imaging tests using a saline phantom demonstrated that the slotted surface coil has deeper RF-sensitivity than the single-loop RF-coil. High quality images of two rats were acquired simultaneously using standard spin-echo pulse sequences, demonstrating that the slotted su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008