Constrained liners, dual mobility or large diameter heads to avoid dislocation in THA

نویسنده

  • Olivier Guyen
چکیده

Dislocation remains a common cause of failure after total hip arthroplasty. The limitations of existing approaches to address instability have led to the development of powerfull options: constrained liners, dual mobility and large heads. These implant-related options have proven to be very efficient, but have raised concerns.With constrained liners, restricted range of motion (ROM) is responsible for impingement leading to high likelihood of failure, depending on the design, with various failure modes.Improvements of the bearing materials have addressed some of the concerns about increased volumetric wear of conventional polyethylene and offer an option to reduce instability: large diameter heads have the advantage of increased ROM before impingement, increased head-neck ratio, and jump distance. Highly cross-linked polyethylene helps address the risk for increased wear, and also large heads provide improved stability without the risk of mechanical failures observed with constrained liners. However, the increase of the head size remains limited as reducing the thickness of the liner may lead to fractures. In addition, the jump distance decreases as the cup abduction increases.The dual mobility concept simultaneously attempts to address head-neck ratio, constraint, and jump distance. Despite the need for longer follow-up, concerns raised about potential increased wear and intra-prosthetic dislocation with first generation implants have been addressed with modern designs.With a dramatic increase of the head-neck ratio whilst reducing the risk of mechanical failure or excessive wear, dual mobility THA outperforms large diameter heads and constrained liners at 10 years follow-up. For these reasons, dual mobility continues to gain interest worldwide and is becoming the most popular option to manage instability. Cite this article: Guyen O. Constrained liners, dual mobility or large diameter heads to avoid dislocation in THA. EFORT Open Rev 2016;1:197-204. DOI: 10.1302/2058-5241.1.000054.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dual poly liner mobility optimizes wear and stability in THA: opposes.

Total hip arthroplasty (THA) is an effective intervention for the treatment of arthrosis with excellent survivorship. Nonetheless, dislocation and osteolysis remain significant complications. A dual-mobility acetabular component has been advocated to improve stability and wear. Stability is imparted by increasing the effective femoral head size, which allows a larger range of motion (ROM) befor...

متن کامل

Early Intraprosthetic Dislocation of Dual- Mobility Total Hip Arthroplasty Implant Following Attempted Closed Reduction: A Case Report

Introduced in 1974 by Bousquet, the dual-mobility bearing for use in total hip arthroplasty (THA) confers increased jump distance and improved overall stability relative to conventional THA designs [1-3]. The dual-mobility bearing incorporates a relatively small (22-28mm) metal or ceramic femoral head press fit into a larger polyethylene liner which articulates with the acetabular component. Di...

متن کامل

Early Intraprosthetic Dislocation of A Dual Mobility Acetabular Construct

Dislocations represent one of the more common postoperative complications seen after total hip arthroplasty (THA) with estimates ranging from 0.2 to 7% in primary cases and as high as 25% in revision surgeries [1]. In the early 1970s, Giles Bousquet developed a dual mobility (DM) acetabular cup with the goal of reducing dislocation rates. The dual mobility (DM) design consists of two articulati...

متن کامل

Constrained liner in neurologic or cognitively impaired patients undergoing primary THA.

BACKGROUND THA performed in patients with cognitive deficits or neuromuscular diseases has been associated with a high postoperative dislocation rate. The constrained liner reportedly provides stability in patients with recurrent dislocation. However, achieving stability could be offset by early loosening when used in patients with neurologic diseases. QUESTIONS/PURPOSES We therefore asked wh...

متن کامل

The Effect of In Vivo Damage of Oxinium Femoral heads on the Wear of Highly Cross-linked Polyethylene

Bragdon, C.R; Wannomae, K. K.; Lozynsky, A.; Micheli, B.; Malchau, H. Harris Orthopaedic Biomechanics and Biomaterials Laboratory, Massachusetts General Hospital, Boston, MA 02114 Senior author [email protected] INTRODUCTION: Oxidized zirconium (OxiniumTM) is a bearing surface introduced for use in THA to minimize wear in vivo. Oxinium femoral heads are manufactured by oxidizing wrought Zr-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2016