Material Analysis of Spontaneously Subluxated Iris-Fixated Phakic Intraocular Lenses.

نویسندگان

  • Tamer Tandogan
  • Mike P Holzer
  • Chul Young Choi
  • Gerd U Auffarth
  • Georg Gerten
  • Ramin Khoramnia
چکیده

PURPOSE To conduct a material analysis of spontaneously subluxated iris-fixated phakic intraocular lenses (IOLs) using light and scanning electron microscopy. METHODS Six explanted Artisan/Verisyse and Artiflex/Veriflex IOLs (Ophtec, Groningen, Netherlands/AMO, Santa Ana, CA) were analyzed in a laboratory using light and scanning electron microscopy. Four of the IOLs had been explanted after spontaneous subluxation leading to a decrease in visual acuity, whereas the remaining two IOLs did not demonstrate signs of disenclavation but had been explanted in the course of planned cataract surgery and thus served as the control in this study. RESULTS Light microscopy enabled the detection of clear deformations of the fixation arms on one or both haptics of the lens that had subluxated, and scanning electron microscopy revealed micro-cracks in the material. The deformations, which appeared to have been caused by some form of manipulation of the fixation arms, meant that adequate closure of the fixation arms was no longer possible and a reliable fixation in the iris stroma was unattainable. At least three of the lenses had been implanted with the use of an IOL haptic expander for enclavation, which may have contributed to the malformation of the haptics. The two control lenses exhibited no signs of material deformation or subsequent disenclavation. CONCLUSIONS Deformations of the haptics of iris-fixated phakic IOLs can cause irreversible damage leading to disenclavation and inadequate re-enclavation. In such cases, explantation appears to be the only therapeutic option. It is important to adhere to an appropriate implantation technique to reduce the risk of spontaneous subluxation. [J Refract Surg. 2016;32(9):618-624.].

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artisan iris-fixated toric phakic intraocular lens for the correction of high astigmatism after deep anterior lamellar keratoplasty.

We report the refractive correction of high astigmatism in one eye of a 23-year-old woman following deep anterior lamellar keratoplasty (DALK) using an Artisan iris-fixated, toric, phakic intraocular lens (IOL). One year after implantation, uncorrected and corrected distance visual acuities were both 20/25, refraction was -1.00 D cylinder, and the endothelial cell count was 1827 cells/mm(2). Ir...

متن کامل

Implantation of phakic intraocular lens in 3 patients with oculocutaneous albinism.

UNLABELLED We present 3 cases with oculocutaneous albinism in which a high refractive error was optically corrected by implantation of an Artisan iris-fixated phakic intraocular lens, with a follow-up of 8 to 14 years. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.

متن کامل

Scanning electron microscopic characteristics of phakic intraocular lenses.

OBJECTIVE To analyze the surface quality of new generation phakic intraocular lenses (IOLs). DESIGN Experimental materials study. MATERIALS Three different new generation phakic IOLs: angle-fixated anterior chamber lens Chiron Vision NuVita MA20 (polymethylmethacrylate [PMMAD, iris-fixated anterior chamber lens Ophtec Artisan Iris-Claw (PMMA), posterior chamber lens Staar ICM (polymer from ...

متن کامل

Anterior chamber iris-fixated phakic intraocular lens for anisometropic amblyopia.

We report a child who had implantation of an iris-fixated Artisan phakic intraocular lens (IOL) to correct high unilateral myopia to support the therapy of anisometropic amblyopia. After IOL implantation, the patient continued occlusion therapy to further treat the amblyopic eye. One year postoperatively, the best corrected visual acuity in the amblyopic eye was 1.00 and binocular stereovision ...

متن کامل

Iris-fixated phakic intraocular lens implantation for correction of high myopia in microspherophakia.

We report the refractive correction of high myopia in a 23-year-old patient with idiopathic microspherophakia using iris-fixated phakic intraocular lenses (pIOLs) (Verisyse/Artisan). Four years after bilateral implantation, the uncorrected distance visual acuity was 20/25 with a correction of 20/20(-1) in both eyes. No intraoperative or postoperative complications occurred. Iris-fixated pIOLs a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 32 9  شماره 

صفحات  -

تاریخ انتشار 2016