Benzodiazepines: toxic serum concentrations in positive enzyme immunoassay responses.

نویسندگان

  • F Divanon
  • D Debruyne
  • M Moulin
  • R Leroyer
چکیده

A total of 588 blood specimens collected in an emergency unit were screened for benzodiazepines (BZDs) using enzyme-multiplied immunoassay and gas chromatography. Two-hundred eighty-five samples were positive for BZDs, and 303 samples that were negative by EMIT included 20 samples with BZDs detectable by gas-liquid chromatography. A total of 15 BZDs were identified, and the most frequently occurring were nordiazepam, bromazepam, diazepam, and alprazolam. Individual BZDs were found in 74% of cases, but some samples contained two, three, or even four BZDs. There is a risk of missing intoxication by BZDs with low therapeutic range and/or low cross-reactivity (alprazolam, bromazepam, flunitrazepam). There is a risk of misinterpreting a positive result for some BZDs with high therapeutic range and/or high cross-reactivity (nordiazepam), which may reflect a pharmacologically ineffective concentration. A semiquantitative analysis is inappropriate even when the identity of BZD is known. Immunoassays are the only methods presently available for use in emergencies, but physicians must be clearly informed of their limitations and interpret results with caution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of an enzyme immunoassay for determining diazepam and nordiazepam in serum and urine.

We evaluated a commercially available enzyme immunoassay method for determining the concentration of total diazepam plus its active metabolite, nordiazepam, in small amounts of serum and urine. The coefficients of variation were 5% within assay and 8% between assay. Concentrations so measured for patients' sera correlated well with those obtained both by gas chromatography with electron-capture...

متن کامل

Enzymatic hydrolysis improves the sensitivity of Emit screening for urinary benzodiazepines.

Screening for benzodiazepines is routinely performed by immunochemical analysis such as enzyme immunoassay. However, the wide range of therapeutic and toxic concentrations of the different benzodiazepines and their extensive metabolisation and conjugation hamper the design of an immunoassay protocol that can detect all benzodiazepines and their corresponding urinary metabolites. Only a few inve...

متن کامل

Improved screening for benzodiazepine metabolites in urine using the Triage Panel for Drugs of Abuse.

Screening for benzodiazepines is an important component of many drug testing programs. Current immunochemical methods are limited by a lack of sensitivity to many of the 35 forms of benzodiazepines available and because the antibodies used are insensitive to the glucuronic acid conjugates that constitute the major metabolites in urine. The Triage Panel for Drugs of Abuse (Biosite Diagnostics), ...

متن کامل

Investigation of interference by nonsteroidal anti-inflammatory drugs in urine tests for abused drugs.

Anecdotal and uncontrolled studies have suggested that nonsteroidal anti-inflammatory drugs produce false-positive results in immunoassay urine tests for some drugs of abuse. This study was performed in 60 volunteers who took ibuprofen as either a single 400-mg dose, or 200 mg three times a day, or 400 mg three times a day, and in 42 patients taking ibuprofen, naproxyn, or fenoprofen in therape...

متن کامل

Oxaprozin interference with urinary benzodiazepine immunoassays and noninterference with receptor assay.

Immunoassay methods are widely used to screen for urinary benzodiazepines despite several reports of false-positive and false-negative results (1). False-negative results are produced for certain benzodiazepines that have no or low cross-reactivity with the immunoassay used. False-positive results were produced by four commercial immunoassays (Behring EMIT d.a.u., Behring EMIT II, Abbott FPIA, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 22 7  شماره 

صفحات  -

تاریخ انتشار 1998