Determination of appropriate recording force for non-invasive measurement of arterial pressure pulses.

نویسندگان

  • M D Driscoll
  • M O Arnold
  • G E Marchiori
  • L A Harker
  • M H Sherebrin
چکیده

1. Non-invasive recording techniques of the arterial pressure pulse will distort the arterial wall and may alter pulse wave measurements. We hypothesized that intersubject variability of these measurements would be reduced if recording forces were normalized to reflect individualized arterial occlusion forces. 2. In 10 normal male subjects (age 24 +/- 1 years), brachial, radial and finger arterial pressure pulses were recorded simultaneously using volume displacement pulse transducers (Fukuda TY-303) and a finger pressure monitoring system (Finapres, Ohmeda 2300) and were made at 2, 5 and 10-100% (10% increments) of the brachial arterial force associated with marked distortion of finger pulsations. Forces were applied at the brachial site in a randomized order while a constant 1.8 N force was applied at the radial artery site. Pressure pulses were analysed using the discrete fast Fourier transform. 3. Pulse amplitude, contour, wave velocity and relative transmission ratios remained relatively constant until the branchial artery recording force exceeded 59.9 +/- 0.3% of the largest recording force used in each subject (7.14 +/- 0.75 N). The finger pulse pressures (P < 0.0001), radial pulse amplitudes (P < 0.0001) and contours (harmonics 2-6, P < 0.003), pulse wave velocity (P < 0.021) and relative transmission ratios (harmonics 3-7, P < 0.01) then decreased with higher recording forces. 4. To avoid distortion, non-invasive recordings of arterial pressure pulse amplitude, contour, pressure wave velocity and relative transmission ratios along a peripheral arterial segment should use recording forces of less than 60% of the force associated with marked distortion of finger pulsations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

برآورد سرعت موج پالس با استفاده از پارامترهای شریانی استخراج شده از تصاویر فراصوتی کاروتید

  Background & Objective : Several indices have been introduced to estimate arterial stiffness that based on changes in brachial blood pressure. But because of the error resulted by the substitution of brachial blood pressure instead of the other central arteries, such as carotid, it will be very important to present elastic parameter based on the mechanical models without any emphasis on brach...

متن کامل

Non-invasive Optical Techniques for determination of blood Glucose levels: A Review Article

This article reviews the development of non-invasive optical techniques for determination of blood glucose concentrations in diabetic patients. Early diagnosis and daily management are essential for ensuring the healthy life of diabetic patients. The determination of blood glucose concentration with common devices involves the chemical analysis of blood samples, which are obtained by pricking t...

متن کامل

Standardization and Validation of Non-invasive Monitoring of End Tidal Carbon Dioxide in Neonates via Nasal Cannula: An Observational Study

Background: Carbon dioxide (CO2) is a by-product of cellular metabolism, which could be considered as a reflection of metabolism, circulation, and ventilation. Arterial blood gas analysis (ABG) is the gold standard of monitoring for CO2. However, is an expensive method leading to blood loss and iatrogenic anemia. In addition, each sample is only a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical science

دوره 92 6  شماره 

صفحات  -

تاریخ انتشار 1997