Stentless porcine valves in the right ventricular outflow tract: improved durability?

نویسندگان

  • John A Hawkins
  • Christopher Todd Sower
  • Linda M Lambert
  • Peter C Kouretas
  • Phillip T Burch
  • Aditya K Kaza
  • Michael D Puchalski
  • Angela T Yetman
چکیده

OBJECTIVE Stentless porcine valves are commonly used for aortic valve replacement in adults, yet their long-term performance in the right ventricular (RV) outflow tract is unknown. We evaluated intermediate-term performance of stentless porcine valves in the RV outflow tract in 150 children and adults over a 10-year period. METHODS We retrospectively reviewed data on all patients undergoing placement of a pulmonary valve or RV-PA conduit with a stentless porcine prosthesis (>/=19 mm) from 1998 to 2008. Valvar function was assessed with echocardiography. Freedom from reintervention (explantation or catheter-based intervention) was determined by actuarial methods. RESULTS A stentless porcine prosthesis was placed in the pulmonary position in 150 patients with a median weight and age of 50.1 kg (range 9.8-127) and 15.8 years (range 1.4-55), respectively. There were three early deaths (2%) and no late deaths. Actuarial freedom from reintervention was 100% at 1 year and 95.5% at 5 years. Peak transvalvar gradient at 1 and 5 years was 13+/-12 mmHg and 25+/-11 mmHg, respectively. At last follow-up no patient had severe insufficiency (PI), five patients had moderate PI and the remainder mild or no PI. CONCLUSIONS Stentless porcine valves function well in the pulmonary position over the intermediate-term and are associated with low rates of reintervention in patients requiring a >19 mm valve or valved conduit. Longer-term follow-up and comparison with other alternatives will be necessary to determine if these valves are superior to commonly used allograft or bovine jugular venous valved conduits.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ross operation and right ventricular outflow tract reconstruction with stentless xenografts.

Traditionally a homograft valve is used as a pulmonary replacement device for the Ross operation. Right ventricular outflow tract reconstruction during aortic valve replacement with an autograft was performed with stentless xenograft valves in nine patients. Hemodynamic performance is satisfying, but, long term evaluation is needed.

متن کامل

Stentless aortic valve replacement: an update

Although porcine aortic valves or pericardial tissue mounted on a stent have made implantation techniques easier, these valves sacrifice orifice area and increase stress at the attachment of the stent, which causes primary tissue failure. Optimizing hemodynamics to prevent patient-prosthetic mismatch and improve durability, stentless bioprostheses use was revived in the early 1990s. The purpose...

متن کامل

Stentless Aortic Valve/Root Replacement

In-vitro, stentless valves have a larger effective orifice area than their stented counterparts. This is best exemplified by the fact that a 25-mm Mosaic valve, which is stented, is manufactured using a 23-mm Freestyle stentless valve. So, in order to end-up with similar effective orifice areas when implanting a stentless valve or a stented valve in the same size left ventricular outflow tract,...

متن کامل

Magnetic resonance imaging of stentless xenografts for reconstruction of right ventricular outflow tract.

The objective was to overcome allograft shortage during the Ross operation; stentless xenografts were carefully evaluated for hemodynamic behavior and valve deterioration during medium term follow-up. Between January 10, 1994 and January 4, 1996 nine adult patients (age 31-51 years) underwent aortic valve replacement with an autologous pulmonary valve and right ventricular outflow tract reconst...

متن کامل

Tissue engineering of an auto-xenograft pulmonary heart valve.

To improve the durability of stentless valves without losing their excellent hemodynamic function, a new-generation auto-xenograft was developed and evaluated. A piece of vein was harvested from 3 juvenile sheep 6 weeks before implantation of the valve. Endothelial cells from the vein material were cultivated and used to reendothelialize a decellularized porcine pulmonary valve. The tissue-engi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 35 4  شماره 

صفحات  -

تاریخ انتشار 2009