Patient-specific prediction of intrinsic mechanical loadings on sub-muscular pectoral pacemaker implants based on an inter-species transfer function.

نویسندگان

  • Michael Hamman de Vaal
  • James Neville
  • Micah Litow
  • Jacques Scherman
  • Peter Zilla
  • Thomas Franz
چکیده

With the steady technological development enabling reduced device dimensions and new patient populations, detailed data on mechanical in vivo loads become increasingly important to ensure reliability of implantable medical devices. Based on an intra-species correlation of in-line and transverse force of the Pectoralis major established previously for the Chacma baboon (de Vaal et al., 2010a), a simplified physiological model and a mechanical equivalent model were developed for a sub-muscular pectoral device implant considering Pectoralis major, Pectoralis minor and rib cage. By assessing the morphometric and mechanical parameters of these musculo-skeletal structures and the associated model parameters, the intra-species correlation was shown to exhibit (a) robustness for a larger intra-species subject population and (b) linear scale variance allowing application for humans under consideration of the inter-species difference of the attachment angles of Pectoralis major. The transfer function provides a basis for the prediction of patient-specific maximum mechanical loadings on a sub-muscular pectoral cardiac pacemaker implant through non- or minimal invasive measurements on the patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dry Reforming of Methane Using Cold Plasma; Kinetic Model Study

In this work, the dry reforming of methane was studied using a corona and gliding discharge plasma microreactors. A chemical kinetic model was developed to describe the experimental behavior observed. The kinetic model is proposed based on the assumption that the reactant molecules CH4 or CO2 are attacked by active species produced b...

متن کامل

Heat Transfer Coefficients Investigation for TiO2 Based Nanofluids

From a regression analysis perspective, this paper focused on literature about TiO2 nano particles. The particles on focus entailed those that had been suspended in ethylene glycol and water – at a ratio of 60:40. Indeed, regression analysis has gained application in contexts such as the turbulent Reynolds number, especially with the aim of establishing the impact of the ratio of the...

متن کامل

Pectoral muscular twitching: a rare manifestation of spontaneous twiddler syndrome

The twiddler syndrome is an uncommon cause of pacemaker malfunction, in which twisting or rotating of the device in its pocket results in lead retraction or coiling and subsequent malfunction of an implanted devices such as a pacemaker, an implantable cardioverter-defibrillator (ICD), cardiac resynchronization therapy (CRT).  This report describes a rare case of twiddler syndrome after implant...

متن کامل

Analytical Solution of Stress Field in Adhesively Bonded Composite Single-Lap Joints Under Mechanical Loadings

In this paper, considering an adhesively bonded composite single-lap joint, a novel approach is presented to predict the peel and shear stress distributions of the adhesive layer for an ASTM standard test sample. In current method, the equilibrium equations are derived using the energy method and based on the Timoshenko’s beam theory. Two solution procedures then are discussed, one of which rep...

متن کامل

Electromagnetic Interference on Pacemakers

External sources, either within or outside the hospital environment, may interfere with the appropriate function of pacemakers which are being implanted all around the world in current medical practice. The patient and the physician who is responsible for follow-up of the pacing systems may be confronted with some specific problems regarding the various types of electromagnetic interference (EM...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 44 14  شماره 

صفحات  -

تاریخ انتشار 2011