Comparison of methods of automatic blood pressure measurement in the same device
نویسندگان
چکیده
Comparison of tacho-oscillographic and oscillometric methods for human blood pressure measurement with cuff occlusion in the same device at the same time is described. For this purpose the measurement system and software for signal processing that realize these methods in the same device was developed. Experiment shows that oscillometric method with photoplethysmographic (PPG) sensors does not require empiric criteria to search systolic and diastolic blood pressure parameters due to possibility to apply correlation analysis. Perspectives of applying oscillometric method with PPG sensors in automatic blood pressure monitors is showed. Keywords—blood pressure measurement; oscillometric method; PPG; plethysmography; correlation analysis
منابع مشابه
Comparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement
Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...
متن کاملتخمین بدون کاف فشارخون مبتنی بر ویژگیهای زمانی سیگنال نبض
Blood pressure is one of the vital signs. Specially, it is crucial for some cases such as hypertension patients and it should be monitored continuously in ICU/CCU. It must be noted that current systems to measure blood pressure, often require trained operators. As an example, in post-hospital cares, blood pressure control is difficult except with the presence of a nurse or use of a device that ...
متن کاملComparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study
Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...
متن کاملThe role of stress on the rise of blood pressure
Background: The virtual rise of blood pressure resulted from stress, that is observed in subjects that are tested in medical centers, can be oftenly corrected by holter. This phenomenon causes such persons not to response to the common anti blood pressure treatments (2). Materials and methods: This descriptive study was conducted 2006-2007 at the heart clinic of Shohadaye–Ashayer hospital in Kh...
متن کاملStudying Changes of the Effective Radius in Blood Vessels after Exposure of Lower Extremities to Periodical Mechanical Vibrations
Background: Previous studies demonstrated a health improving effect in patients underwent an automatic vibratory massage taking 10 minutes. One of reasons that may explain a healing effect of the automatic massage is a stimulated increase in both blood circulation through vascular system and effective size of blood vessels. Objective: This paper aims to quantify a contribution of the auto...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- CoRR
دوره abs/1506.05947 شماره
صفحات -
تاریخ انتشار 2015