Impedance based DNA chip for direct T(m) measurement.
نویسندگان
چکیده
Si/SiO(2) chips were used to detect the hybridization of immobilized Oligo d(T)(20) through impedance measurement. The immobilization procedure involved an aminopropyl silane grafted silicon oxide surface activated by glutaraldehyde and subsequently modified by an aminolinker supporting oligonucleotides. The immobilization procedure was optimized and, in the best conditions, the hybridization of the immobilized oligonucleotide was able to generate a 50 Omega impedance change at an applied dc potential of -300 mV. The optimized DNA sensor was then used to directly determine the immobilized oligonucleotide T(m) via impedance measurement in a continuous temperature control flow system. A reproducible and specific 65 Omega impedance change was observed at 32 degrees C with a step duration as low as 15 min. This value compared well with the 31.4 degrees C theoretical value calculated from the sequence base pair composition and length.
منابع مشابه
Impedance-Based Out-of-Step Protection of Generator in the Presence of STATCOM
This paper presents a novel impedance-based approach for out-of-step (OOS) protection of a synchronous generator. The most popular and commonly used approaches for detecting OOS conditions are based on the measurement of positive sequence impedance at relay location. However, FACTS devices change the measured impedance value and thus disrupt the performance of impedance-based relay function. In...
متن کامل. in s - de t ] 2 7 Ju l 2 01 0 Atom chips on direct bonded copper substrates
We present the use of direct bonded copper (DBC) for the straightforward fabrication of high power atom chips. Atom chips using DBC have several benefits: excellent copper/substrate adhesion, high purity, thick (> 100 μm) copper layers, high substrate thermal conductivity, high aspect ratio wires, the potential for rapid (< 8 hr) fabrication, and three dimensional atom chip structures. Two mask...
متن کاملControllable in-situ cell electroporation with cell positioning and impedance monitoring using micro electrode array
This paper reports a novel microarray chip for in-situ, real-time and selective electroporation on individual cells integrated with cell positioning and impedance monitoring. An array of quadrupole-electrode units (termed positioning electrodes) and pairs of planar center electrodes located at the centers of each quadrupole-electrode unit were fabricated on the chip. The positioning electrodes ...
متن کاملResearch on Measurement System of High-Frequency Parameters for Line Traps
The composing of high frequency line trap of power system is briefly introduced, A new method based on improved voltage meter method is presented, which can measure the frequency-impedance characteristic of the line trap of power system. A new testing arithmetic is presented based on the correlation principle, Cross-correlation functions of the two measured signals are directly computed and som...
متن کاملThermo-Electro Mechanical Impedance based Structural Health Monitoring: Euler- Bernoulli Beam Modeling
In recent years, impedance measurement method by piezoelectric (PZT) wafer activesensor (PWAS) has been widely adopted for non-destructive evaluation (NDE). In this method, theelectrical impedance of a bonded PWAS is used to detect a structural defect. The electro-mechanicalcoupling of PZT materials constructs the original principle of this method. Accordingly, the electricalimpedance of PWAS c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Talanta
دوره 56 4 شماره
صفحات -
تاریخ انتشار 2002