Noninvasive reduction of open-book pelvic fractures by circumferential compression.

نویسندگان

  • Michael Bottlang
  • Tamara Simpson
  • Juergen Sigg
  • James C Krieg
  • Steven M Madey
  • William B Long
چکیده

OBJECTIVES To determine the efficacy and optimal application parameters of circumferential compression to reduce external rotation-type pelvic fractures. DESIGN Biomechanical investigation on human cadaveric specimens. SETTING Biomechanics laboratory. INTERVENTION Partially stable and unstable external rotation injuries of the pelvic ring (OTA classification 61-B1 and 61-C1) were created in seven human cadaveric specimens. A prototype pelvic strap was applied subsequently at three distinct transverse levels around the pelvis. Circumferential pelvic compression was induced by gradual tensioning of the strap to attempt complete reduction of the symphysis diastasis. MAIN OUTCOME MEASUREMENTS Pelvic reduction was evaluated with respect to strap tension and the strap application site. The effect of circumferential compression on intraperitoneal pressure and skin-strap interface pressure was measured. RESULTS A successive increase in circumferential compression consistently induced a gradual decrease in symphysis diastasis. An optimal strap application site was determined, at which circumferential compression most effectively yielded pelvic reduction. The minimum strap tension required to achieve complete reduction of symphysis diastasis was determined to be 177 +/- 44 Newtons and 180 +/- 50 Newtons in the partially stable and unstable pelvis, respectively. CONCLUSIONS Application of circumferential compression to the pelvic soft tissue envelope with a pelvic strap was an efficient means to achieve controlled reduction of external rotation-type pelvic fractures. This study derived application parameters with direct clinical implication for noninvasive emergent management of traumatic pelvic ring disruptions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stabilization of pelvic ring disruptions with a circumferential sheet.

Pelvic ring disruptions in the polytraumatized patient are associated with a mortality rate of up to 25%.1 Acute uncontrolled hemorrhage and its complications are the leading causes of death in these patients.2 Treatment algorithms for resuscitation and control of hemorrhage are aimed at reducing morbidity and mortality. Although variations exist among these algorithms, essentially all include ...

متن کامل

Emergent stabilization of pelvic ring injuries by controlled circumferential compression: a clinical trial.

BACKGROUND Pelvic ring injuries are associated with a high incidence of mortality mainly due to retroperitoneal hemorrhage. Early stabilization is an integral part of hemorrhage control. Temporary stabilization can be provided by a pelvic sheet, sling, or an inflatable garment. However, these devices lack control of the applied circumferential compression. We evaluated a pelvic circumferential ...

متن کامل

The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation

 Abstract Background: Unstable Pelvic fracture, a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This st...

متن کامل

Comparison of three different pelvic circumferential compression devices: a biomechanical cadaver study.

BACKGROUND Pelvic circumferential compression devices are designed to stabilize the pelvic ring and reduce the volume of the pelvis following trauma. It is uncertain whether pelvic circumferential compression devices can be safely applied for all types of pelvic fractures because the effects of the devices on the reduction of fracture fragments are unknown. The aim of this study was to compare ...

متن کامل

Effectiveness and complications of pelvic circumferential compression devices in patients with unstable pelvic fractures: a systematic review of literature.

BACKGROUND Pelvic fractures can cause massive haemorrhage. Early stabilisation and compression of unstable fractures is thought to limit blood loss. Reposition of fracture parts and reduction of pelvic volume may provide haemorrhage control. Several non-invasive techniques for early stabilisation have been proposed, like the specifically designed pelvic circumferential compression devices (PCCD...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic trauma

دوره 16 6  شماره 

صفحات  -

تاریخ انتشار 2002