Iodine concentration calculated by dual-energy computed tomography (DECT) as a functional parameter to evaluate thyroid metabolism in patients with hyperthyroidism
نویسندگان
چکیده
BACKGROUND Thyroid function in patients with Grave's disease is usually evaluated by thyroid scintigraphy with radioactive iodine. Recently, dual-energy computed tomography (DECT) with two different energy X-rays can calculate iodine concentrations and can be applied for iodine measurements in thyroid glands. This study aimed to assess the potential use of DECT for the functional assessment of the thyroid gland. METHODS Thirteen patients with Grave's disease treated at our hospital from May to September 2015 were included in this retrospective study. Before treatments, all subjects had undergone both iodine scintigraphy [three and 24 h after oral administration of 123I (20 μCi)] and non-enhanced DECT. The region of interests (ROIs) were placed in both lobes of the thyroid glands, and CT values (HU: Hounsfield unit) and iodine concentrations (mg/mL) calculated from DECT images were measured. The correlation between CT values and iodine concentrations from DECT in the thyroid gland was evaluated and then the iodine concentrations were compared with radioactive iodine uptake ratios by thyroid scintigraphy. RESULTS Mean (±SD) 123I uptake increased from 46.3 (±22.2) % (range, 11.1-80.1) at 3 h, to 66.5 (±15.2) % (range, 40.0-86.1) at 24 h (p < 0.01). CT values ranged from 34.5 to 98.7 HU [mean: 67.8 (±18.6)], while the iodine concentrations calculated with DECT ranged from 0.0 to 1.3 mg/mL [mean: 0.5 (±0.4)]. A moderate positive correlation between CT values and the calculated iodine concentrations in the thyroid gland was seen (R = 0.429, p < 0.05). A significant negative correlation between 123I uptake at 3 h and iodine concentration by DECT were seen (R = -0.680, p < 0.05), although no correlation was observed between 123I uptake at 3 h and CT values (p = 0.087). No correlation was observed between 123I uptake at 24 h and CT values (p = 0.153) or that between 123I uptake at 24 h and iodine concentration by DECT (p = 0.073). CONCLUSION The negative correlation of 123I uptake at 3 h with iodine concentration evaluated by DECT was better than that observed with simple CT value. DECT may have a potential role in the evaluation of iodine turnover in hyperthyroid patients.
منابع مشابه
Dual-energy CT in colorectal cancers: beyond the density measurements.
I read with interest the article by Özdeniz et al. (1), on dual-source dual-energy computed tomography (DECT) to differentiate fecal matter from neoplasm. The study was well done and was based on density measurements in iodine maps and virtual unenhanced images. I would like to add a few points to the discussion. The main advantage of DECT is material decomposition and the relative iodine conce...
متن کاملMonitoring targeted therapy using dual-energy CT: semi-automatic RECIST plus supplementary functional information by quantifying iodine uptake of melanoma metastases
AIM Supplementary functional information can contribute to assess response in targeted therapies. The aim of this study was to evaluate semi-automatic RECIST plus iodine uptake (IU) determination in melanoma metastases under BRAF inhibitor (vemurafenib) therapy using dual-energy computed tomography (DECT). METHODS Nine patients with stage IV melanoma treated with a BRAF inhibitor were include...
متن کاملAccuracy of dual‐energy computed tomography for the quantification of iodine in a soft tissue‐mimicking phantom
The objective of this study was to evaluate the accuracy of dual-energy CT (DECT) for quantifying iodine using a soft tissue-mimicking phantom across various DECT acquisition parameters and dual-source CT (DSCT) scanners. A phantom was constructed with plastic tubes containing soft tissue-mimicking materials with known iodine concentrations (0-20 mg/mL). Experiments were performed on two DSCT s...
متن کاملDifferentiation of malignant cervical lymphadenopathy by dual-energy CT: a preliminary analysis
The accurate diagnosis of malignant cervical lymphadenopathy remains challenging. In this study, we determined the value of quantitative parameters derived from dual-energy computed tomography (DECT) for differentiating malignant cervical lymphadenopathy caused by thyroid carcinoma (TC), salivary gland carcinoma (SC), squamous cell carcinoma (SCC) and lymphoma. We retrospectively analysed 92 pa...
متن کاملDual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level
OBJECTIVE To optimize the dose of contrast agent and the level of energy for dual-energy computed tomography (DECT) arthrography of the shoulder joint and to evaluate the benefits of the optimized imaging protocol. MATERIALS AND METHODS Dual-energy scans with monochromatic spectral imaging mode and conventional single energy scans were performed on a shoulder phantom with 10 concentrations fr...
متن کامل