A feasibility study on bedside upper airway ultrasonography compared to waveform capnography for verifying endotracheal tube location after intubation

نویسندگان

  • Osman Adi
  • Tan Wan Chuan
  • Manikam Rishya
چکیده

BACKGROUND In emergency settings, verification of endotracheal tube (ETT) location is important for critically ill patients. Ignorance of oesophageal intubation can be disastrous. Many methods are used for verification of the endotracheal tube location; none are ideal. Quantitative waveform capnography is considered the standard of care for this purpose but is not always available and is expensive. Therefore, this feasibility study is conducted to compare a cheaper alternative, bedside upper airway ultrasonography to waveform capnography, for verification of endotracheal tube location after intubation. METHODS This was a prospective, single-centre, observational study, conducted at the HRPB, Ipoh. It included patients who were intubated in the emergency department from 28 March 2012 to 17 August 2012. A waiver of consent had been obtained from the Medical Research Ethics Committee. Bedside upper airway ultrasonography was performed after intubation and compared to waveform capnography. Specificity, sensitivity, positive and negative predictive value and likelihood ratio are calculated. RESULTS A sample of 107 patients were analysed, and 6 (5.6%) had oesophageal intubations. The overall accuracy of bedside upper airway ultrasonography was 98.1% (95% confidence interval (CI) 93.0% to 100.0%). The kappa value (Κ) was 0.85, indicating a very good agreement between the bedside upper airway ultrasonography and waveform capnography. Thus, bedside upper airway ultrasonography is in concordance with waveform capnography. The sensitivity, specificity, positive predictive value and negative predictive value of bedside upper airway ultrasonography were 98.0% (95% CI 93.0% to 99.8%), 100% (95% CI 54.1% to 100.0%), 100% (95% CI 96.3% to 100.0%) and 75.0% (95% CI 34.9% to 96.8%). The likelihood ratio of a positive test is infinite and the likelihood ratio of a negative test is 0.0198 (95% CI 0.005 to 0.0781). The mean confirmation time by ultrasound is 16.4 s. No adverse effects were recorded. CONCLUSIONS Our study shows that ultrasonography can replace waveform capnography in confirming ETT placement in centres without capnography. This can reduce incidence of unrecognised oesophageal intubation and prevent morbidity and mortality. TRIAL REGISTRATION National Medical Research Register NMRR11100810230.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

End-tidal capnography and upper airway ultrasonography in the rapid confirmation of endotracheal tube placement in patients requiring intubation for general anaesthesia

BACKGROUND AND AIMS Confirmation of correct endotracheal tube placement is essential immediately after intubation for general anaesthesia. In this study, we have compared upper airway ultrasonography (USG) with reference to capnography for rapid confirmation of endotracheal tube placement after general anaesthesia. METHODS A prospective, single centre, observational study was conducted on 100...

متن کامل

Laryngo-tracheal ultrasonography to confirm correct endotracheal tube and laryngeal mask airway placement

Waveform capnography was recommended as the most reliable method to confirm correct endotracheal tube or laryngeal mask airway placements. However, capnography may be unreliable during cardiopulmonary resuscitation and during low flow states. It may lead to an unnecessary removal of a well-placed endotracheal tube, re-intubation and interruption of chest compressions. Real-time upper airway (la...

متن کامل

Confirming nasogastric tube position: methods & restrictions: A narrative review

Background and Purpose: Inserting a nasogastric tube, though a common clinical procedure with widespread use for critically ill patients, can produce unexpected complications so that tube misplacement into the lungs is a potential complication with serious consequences. The reliability of common bedside methods to differentiate between pulmonary and gastric placement has not been acceptable. Th...

متن کامل

Anesthesiology and the Difficult Airway – Where Do We Currently Stand?

Anesthesiology has made a significant advance in airway care since the introduction of the facemask and then followed by endotracheal tubes for assisted ventilation. [1] The need for assisted ventilation for the advancement of anesthesia care has resulted in significant improvements in health care for patients needing surgical, diagnostic, and intensive BLOCKINcare. BLOCKINPractitioners BLOCKIN...

متن کامل

Predictive Value of Tracheal Rapid Ultrasound Exam Performed in the Emergency Department for Verification of Tracheal Intubation

BACKGROUND Verification of the correct placement of the endotracheal tube (ETT) has been one of the most challenging issues of airway management in the field of emergency medicine. Early detection of oesophagal intubation through a reliable method is important for emergency physicians. AIM The aim of this study was to assess the diagnostic accuracy of tracheal rapid ultrasound exam (TRUE) to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2013