INTRODUCTION Modern hospital pharmacology insists on assessing each patient's individual characteristics because of their influence on drug pharmacokinetics and pharmacodynamic effect. The study was aimed at evaluating anesthetic doses in patients with benign larynx tumors treated by general endotracheal anesthesia during endoscopic surgery procedures. MATERIAL AND METHODS The study is a part of a prospective, phase IV, academic study carried out at the Clinical Center of Serbia. The evaluation included 30 patients, who were divided into two groups: Group A - 10 patients, anesthetized with standard recommended anesthetic doses. The insight into the obtained bispectral index values was possible only after completion of the surgery. Group B consisted of 20 patients, anesthetized with anesthetic doses corrected according to bispectral index monitoring values. RESULTS The average duration of waking up in group A and B was 120.0 +/- 10.0 sec and B 70.0 +/- 9.0 sec, respectively, (p<0.01). When compared with group A the corrected induction anesthetic doses, corrected maintenance doses and anesthetic total consumption were lower in group B by 25% (p<0.01), 15% (p<0.01) and 25% (p<0.01), respectively. CONCLUSION It is possible to overdose anesthetic drug during surgery without using bispectral index technology monitoring during general anesthesia in otorhinolaryngology maxillofacial surgery. Bispectral index monitoring should be the clinical standard in general anesthesia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Bispectral Index Monitoring Versus Clinical Judgment as a Guide for Conduction of Anesthesia on Serum Cortisol Level in Co-ronary Artery Bypass Graft Surgery

Background: Inadequate depth of anesthesia leads to release of stress hormones. Electroencephalographic monitoring by bispectral index is a guide to asses the depth of anesthesia. The aim of the present study was to measure the serum cortisol levels as an index of stress response in patients who are candidates for coronary artery bypass graft surgery in two groups of patients. Methods: Seventy-...

متن کامل

Novel Incorportation Of Biomedical Engineering Algorithms (bispectral Index Guided Or Anesthetic Concentration Guided) In Real-Time Decision Support To Prevent Intraoperative Awareness Using An Electronic Anesthesia Information Mananagement System

NOVEL INCORPORATION OF BIOMEDICAL ENGINEERINGALGORITHMS (BISPECTRAL INDEX GUIDED OR ANESTHETICCONCENTRATION GUIDED) IN REAL-TIME DECISION SUPPORT TOPREVENT INTRAOPERATIVE AWARENESS USING AN ELECTRONICANESTHESIA INFORMATION MANAGEMENT SYSTEMbyAMY MELANIE SHANKSMay 2015 Advisors: Drs. John M. Cavanaugh and George A. Mashour Major: Biomedical Engineering Degree: Doc...

متن کامل

Bispectral index monitoring, duration of bispectral index below 45, patient risk factors, and intermediate-term mortality after noncardiac surgery in the B-Unaware Trial.

BACKGROUND Postoperative mortality has been associated with cumulative anesthetic duration below an arbitrary processed electroencephalographic threshold (bispectral index [BIS] <45). This substudy of the B-Unaware Trial tested whether cumulative duration of BIS values lower than 45, cumulative anesthetic dose, comorbidities, or intraoperative events were independently associated with postopera...

متن کامل

Evaluation of the Adequacy of General Anesthesia in Cesarean Section by Bispectral Index

Background: Awareness and recall, though not common, are the major hazards of general anesthesia, especially in Cesarean section (C/S) because of the absence of benzodiazepine and opioids for a significant time during anesthesia. In this study, the Bispectral Index (BIS), end-tidal isoflurane, and hemodynamic parameters were examined to evaluate the depth of the routine general anesthetic techn...

متن کامل

مقایسه اثر دوز ثابت و دوز متغیر نگهدارنده پروپوفل بر زمان بیدار شدن با مانیتورینگ شاخص دوطیفی

ABSTRACT Propofol is a IV anesthetic which produces hypnosis and bispectral index (BIS), a parameter derived from the electroencephalograph (EEG), target of this study is comparing wake up time after termiation of surgery at control group which received constant dose of propofol with study group which received variable dose of propofol within BIS monitoring. This study performed on fif...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medicinski pregled

دوره 65 5-6  شماره 

صفحات  -

تاریخ انتشار 2012