[Pseudoaneurysm of the pulmonary autograft following the Ross procedure].

نویسندگان

  • Ana Rodríguez-Almodóvar
  • Dolores Mesa-Rubio
  • Carmen Durán-Torralba
  • Ignacio Muñoz
چکیده

The Ross procedure has emerged as a good alternative for aortic valve disease, particularly in children and young people in whom repair is not possible.1 Although the procedure is safe, complications related to the pulmonary autograft have been described.2 One of these complications has been reported on only two occasions,3,4 but was potentially severe: pseudoaneurysm of the autograft. A total of 200 patients have undergone the Ross procedure at our hospital; we present two who were asymptomatic and diagnosed with a false aneurysm of the pulmonary autograft at 2 years of follow-up, with a different cause in each case. The first was a 27-year-old man who underwent the Ross procedure for severe postendocarditis aortic incompetence. He was admitted one month later for endocarditis on the autograft suture. The patient’s progress was favorable following antibiotic therapy, with the pre-discharge echocardiogram showing that the endocardial vegetation had disappeared and both graft valves were functioning normally. The patient was followed as an outpatient, with 6-month echocardiographic controls. At 24 months postoperatively, the patient was asymptomatic; however, follow-up transthoracic echocardiography revealed severe aortic regurgitation due to dilation of the pulmonary autograft root. In addition, a pulsatile retroaortic outpouching with interior flow was seen at the autograft suture, consistent with a pseudoaneurysm (Figure 1). Ultimately, the pulmonary autograft was replaced with an aortic valve (Bono-Bentall) with good results. The second case was a 37-year-old man who successfully underwent the Ross procedure for severe rheumatic aortic regurgitation. He received regular follow-up, with the twoyear transthoracic echocardiogram showing a pulsatile retroaortic outpouching with interior flow, that was not present in the echocardiogram the previous year and was consistent with a pseudoaneurysm of the autograft. In addition, he had mild dilation of the aortic ring that caused mild aortic regurgitation. Transesophageal echocardiography disclosed the point of entry in the inferior suture of the autograft in the noncoronary sinus, with extension to the left coronary sinus, compromising the origin of the left coronary artery (Figure 2). Ultimately, the patient underwent surgery with aortic valve placement (Bono-Bentall). The cause of pseudoaneurysm of the pulmonary autograft has been discussed in recent years. It has been attributed to structural weakness of the pulmonary autograft which, when exposed to systemic pressures, experiences progressive dilation and localized rupture, thereby originating the point of entry of the pseudoaneurysm.4 In our first case, the pseudoaneurysm could be explained by the presence of postinfection friable tissue, whereas the other could be due to weakness of the pulmonary annulus, despite reinforcement via annuloplasty. Since both pseudoaneurysms were retroaortic, a relatively inaccessible area for surgical control, we suggest monitoring by intraoperative transesophageal echocardiography. A review of our series showed that these 2 patients had no intraoperative study, and therefore this complication might have been avoided. In conclusion, the 2 patients were diagnosed 2 years after the surgery, despite being asymptomatic, confirming that close clinical and echocardiographic follow-up is important. We believe that transthoracic echocardiography, because it is a LETTERS TO THE EDITOR

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pseudoaneurysm of the Pulmonary Autograft Following the Ross Procedure

The Ross procedure has emerged as a good alternative for aortic valve disease, particularly in children and young people in whom repair is not possible.1 Although the procedure is safe, complications related to the pulmonary autograft have been described.2 One of these complications has been reported on only two occasions,3,4 but was potentially severe: pseudoaneurysm of the autograft. A total ...

متن کامل

تعویض دریچه آئورت: مقایسه روش متداول و روش جدید

Background: The usage of pericardium of patient himself, for support of anastomosis lines may carry benefits in patients undergoing aortic valve replacement with pulmonary autograft (Ross). The aim of the present study was to compare the short term results of aortic valve replacement with pulmonary autograft with routine and offered methods. Methods: In a non-randomized clinical trial, 64 pati...

متن کامل

The modified Ross operation using a Dacron prosthetic vascular jacket does prevent pulmonary autograft dilatation at 4.5-year follow-up.

OBJECTIVE Following the Ross operation, pulmonary autografts tend to dilate over time. This study researches the fate of the pulmonary autograft - at 4.5 years following the modified Ross operation - with special reference to the impact of the modification on (a) pulmonary autograft dilatation, (b) the neo-aortic root geometry, (c) neo-aortic valve function and (d) the coronary artery reserve. ...

متن کامل

عوامل خطر تنگی هموگرافت پولمونر پس ازعمل جراحی Ross

Background: The Ross procedure has been known as a good method for aortic valve replacement. Pulmonary allograft postoperative stenosis subsequent to the Ross procedure has been noted as an important disadvantage of this technique, although risk factors related to this complication are not clearly recognized. In this study we evaluate the risk factors of pulmonary allograft stenosis after Ross ...

متن کامل

The Ross Operation: Treatment of Choice for Aortic Valve Disease in Children and Young Adults

1 also called the pulmonary autograft procedure, involves replacement of the diseased aortic valve with the patient’s own pulmonary valve (autograft) and implantation of a biological valve (homograft) in the pulmonary position. It was first described and pioneered by Mr. Donald Ross in 1967 in London. The procedure was popularised in the 1980s when homografts became widely available on both sid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 60 1  شماره 

صفحات  -

تاریخ انتشار 2007