Preconcentration and determination of cadmium by GFAAS after solid-phase extraction with synthetic zeolite.

نویسندگان

  • Hiroaki Minamisawa
  • Ryoko Okunugi
  • Mayumi Minamisawa
  • Satoshi Tanaka
  • Kazunori Saitoh
  • Nobumasa Arai
  • Masami Shibukawa
چکیده

The solid-phase extraction (SPE) method for the preconcentration of trace amounts of cadmium using synthetic zeolite A-4 and its determination by graphite furnace atomic absorption spectrometry (GFAAS) was investigated. The preconcentration conditions, such as the optimum pH range of the sample solution for the adsorption of cadmium and the kind of acid solution for dissolving the cadmium-adsorbed synthetic zeolite A-4, as well as the measurement conditions for the determination of cadmium by GFAAS, e.g., the ashing and atomizing temperature, were investigated. Quantitative recovery of cadmium onto zeolite A-4 from the sample solution over the pH range 2.0 - 9.0 was achieved by the batch method. After the solid-phase (cadmium-adsorbed zeolite A-4) was separated from the sample solution by a membrane filter, it was dissolved in 2.0 cm(3) of 2.0 mol dm(-3) nitric acid. An aliquot of the resulting solution was injected into the graphite furnace. In GFAAS measurements an alternate gas (Ar, 90%; O(2), 10%) was used as a sheath gas, and the ashing temperature and atomizing temperature were 400 degrees C and 1600 degrees C, respectively. The detection limit (3 sigma) for cadmium was 0.002 microg dm(-3). The relative standard deviation at 0.010 microg dm(-3) was 3.5 - 4.5% (n = 5). The proposed method has been successfully applied to the analysis of trace cadmium in environmental water samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Highly sensitive determination of cadmium and lead in leached solutions from ceramic ware by graphite furnace atomic absorption spectrometry coupled with sequential injection-based solid phase extraction method.

A fully automated pretreatment system based on sequential injection solid-phase extraction (SPE) coupled to a graphite furnace atomic absorption spectrometer (Auto-Pret-GFAAS system) was developed to determine trace amounts of cadmium and lead. A handmade minicolumn packed with a chelating resin was used for the preconcentration of both metals. All protocol for the on-line SPE method was contro...

متن کامل

Air-assisted Liquid Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry for Preconcentration and Determination of Trace Amount of Co(II) and Ni(II) Ions in Water Samples

A simple, rapid and efficient method has been developed for the extraction, preconcentration and determination of cobalt (II) and nickel (II) ions in water samples by air-assisted liquid-liquid microextraction (AALLME) coupled with graphite furnace atomic absorption spectrometry (GFAAS). In the proposed method, much less volume of an organic solvent was used as the extraction solvent in the abs...

متن کامل

Determination of Some Polycyclic Aromatic Hydrocarbons in the Caspian Seawater by HPLC Following Preconcentration with Solid-Phase Extraction

A solid-phase extraction (SPE) method for sample clean-up and preconcentration followed by reversed-phase high-performance liquid chromatography (RP-HPLC) with uv detection is reported for determination of polycyclic aromatic hydrocarbons (PAHs) in the caspian seawater. A good resolution was obtained using acetonitrile:water (40:60) as mobile-phase for separation of these compounds. The eff...

متن کامل

Determination of Rhodium(III) Ions by Flame Atomic Absorption Spectrometry after Preconcentration with Modified Magnetic Activated Carbon

A new method for analysis of trace amount of Rh(III) ions by magnetic activated carbon modified with 2,3,5,6-tetra(2-pyridyl)pyrazine (MAC/TPPZ) as the magnetic sorbent has been proposed. The proposed adsorbent was found to be advantageous over conventional solid phase extraction (SPE) in terms of operational simplicity and low time-consuming. The experimental parameters affecting the extractio...

متن کامل

Preconcentration of Hg(II) with novel nano-Fe3O4- sorbents prior to determination by CVAAS

A novel, simple, sensitive and effective method has been developed for preconcentration of Hg(II) on nano-Fe3O4-DOP-ED solid-phase extraction adsorbent. In this paper, Dioctyl phthalate (DOP) was used to encapsulate nano-Fe3O4 and produce a nano-Fe3O4-DOP sorbent based new sorbent was prepared. This was treated with ethylenediamine (ED) in another solvent-free procedure for the formation of a n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 22 5  شماره 

صفحات  -

تاریخ انتشار 2006