Computer-assisted image-guided surgery using the Regulus Navigator.

نویسندگان

  • J S Rousu
  • P E Kohls
  • B Kall
  • P J Kelly
چکیده

The term "frameless image-guided surgery" has become as well-known to surgeons as computerized tomography or operating room microscope over the past several years. The technologies behind this new surgery option include robotic arms, infra-red camera arrays (1D and 2D), ultrasound, robotic microscopes and magnetic field digitizers. The authors have shown the magnetic field technology incorporated in the Regulus Navigator to be a viable, accurate surgeon's tool by first integrating a conventional framed device and magnetic field frameless device, then advancing to the frameless device alone. During surgery a patient's anatomy is first registered to preoperatively acquired radiological data. Surgical instruments are tracked on interactive CT/MRI displays as the surgeon locates his point or volume-in-space within the surgical field and uses his own procedure/technique of choice for surgical treatment. A clinical trial of 221 patients showed an overall mean accuracy of 2.56 mm with a standard deviation of 1.15 mm for intraoperative registration. Major concerns of utilizing magnetic field technology in the operating room, such as interference from surrounding metallic objects and equipment, were proven manageable while maintaining acceptable accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endoscopic transnasal removal of an intraconal foreign body using an image-guided surgical system.

Foreign bodies lodged in the intraconal space of the orbit pose a surgical challenge due to its deep location behind the globe. Image-guided endoscopic transnasal surgery facilitates the localization of the metallic foreign bodies and enables its safe removal with minimal surrounding tissue damage and optic nerve injury.

متن کامل

White Paper: challenges and opportunities in computer-assisted interventions

In late June 2000, researchers at the forefront of radiology, surgery, and engineering presented the latest advances in medical imaging technologies and image-guided surgery at the annual conference of Computer Assisted Radiology and Surgery (CARS). This document highlights presentations from the panel representing the International Society for Computer Assisted Surgery (ISCAS), along with inpu...

متن کامل

Study On Robot-Assisted Minimally Invasive Neurosugery and its Clinical Application

This paper introduces the research project of robot assisted minimally invasive neurosurgery. Using visualization technology, the system reconstructs and displays the 3D model of the patient’s inner structure in the computer. Thus the surgeons can make the surgery planning on the model in the computer. Marker registration is used to create the mapping between the patient’s head and the 3D-brain...

متن کامل

Computer-assisted spinal navigation versus serial radiography and operative time for posterior spinal fusion at L5-S1.

OBJECTIVE To review the operative time differences between computer-assisted spinal navigation versus serial radiography. SUMMARY OF BACKGROUND DATA There have been multiple studies describing the use of computer-assisted image guided surgery (IGS) in the application of spinal instrumentation. Techniques have evolved to allow attainment of multilevel visualization intraoperatively both succes...

متن کامل

Registration and immobilization in robot-assisted surgery.

Robotic systems for computer-assisted surgery involve both tools and techniques that are new to the surgical arena. Registration and immobilization in particular are key problems. Registration is the spatial alignment of the coordinate frames of the robot, an anatomic object (e.g., a bone), and the preoperative plan (a computer model). Immobilization is necessary to maintain that alignment. We ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Studies in health technology and informatics

دوره 50  شماره 

صفحات  -

تاریخ انتشار 1998