Evaluation of diffusivity in the anterior lobe of the pituitary gland: 3D turbo field echo with diffusion-sensitized driven-equilibrium preparation.

نویسندگان

  • A Hiwatashi
  • T Yoshiura
  • O Togao
  • K Yamashita
  • K Kikuchi
  • K Kobayashi
  • M Ohga
  • S Sonoda
  • H Honda
  • M Obara
چکیده

BACKGROUND AND PURPOSE 3D turbo field echo with diffusion-sensitized driven-equilibrium preparation is a non-echo-planar technique for DWI, which enables high-resolution DWI without field inhomogeneity-related image distortion. The purpose of this study was to evaluate the feasibility of diffusion-sensitized driven-equilibrium turbo field echo in evaluating diffusivity in the normal pituitary gland. MATERIALS AND METHODS First, validation of diffusion-sensitized driven-equilibrium turbo field echo was attempted by comparing it with echo-planar DWI. Five healthy volunteers were imaged by using diffusion-sensitized driven-equilibrium turbo field echo and echo-planar DWI. The imaging voxel size was 1.5 × 1.5 × 1.5 mm(3) for diffusion-sensitized driven-equilibrium turbo field echo and 1.5 × 1.9 × 3.0 mm(3) for echo-planar DWI. ADCs measured by the 2 methods in 15 regions of interests (6 in gray matter and 9 in white matter) were compared by using the Pearson correlation coefficient. The ADC in the pituitary anterior lobe was then measured in 10 volunteers by using diffusion-sensitized driven-equilibrium turbo field echo, and the results were compared with those in the pons and vermis by using a paired t test. RESULTS The ADCs from the 2 methods showed a strong correlation (r = 0.79; P < .0001), confirming the accuracy of the ADC measurement with the diffusion-sensitized driven-equilibrium sequence. The ADCs in the normal pituitary gland were 1.37 ± 0.13 × 10(-3) mm(2)/s, which were significantly higher than those in the pons (1.01 ± 0.24 × 10(-3) mm(2)/s) and the vermis (0.89 ± 0.25 × 10(-3) mm(2)/s, P < .01). CONCLUSIONS We demonstrated that diffusion-sensitized driven-equilibrium turbo field echo is feasible in assessing ADC in the pituitary gland.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffusion-weighted imaging of the pituitary gland.

In this issue of the American Journal of Neuroradiology, you will find the article “Evaluation of Diffusivity in the Anterior Lobe of the Pituitary Gland: 3D Turbo Field Echo with Diffusion-Sensitized Driven-Equilibrium Preparation” by Hiwatashi et al. I enjoyed reading this article and found it to be a nice “proof of principle” regarding the use of “diffusion-sensitized driven-equilibrium turb...

متن کامل

Improvement of T1 contrast in whole-brain black-blood imaging using motion-sensitized driven-equilibrium prepared 3D turbo spin echo (3D MSDE-TSE).

We demonstrated a new scheme for performing the T1-enhanced whole-brain black-blood imaging pulse sequence using motion-sensitized driven-equilibrium prepared 3-dimensional (3D) turbo spin echo (MSDE-TSE) with anti-driven-equilibrium post pulse. The use of an anti-driven-equilibrium pulse considerably improved the T1 contrast of MSDE-TSE black-blood images. This sequence can be used for whole-b...

متن کامل

Assessment of motion sensitized driven equilibrium (MSDE) improvement for whole brain application

INTRODUCTION: Contrast-Enhancement (CE) magnetic resonance imaging (MRI) is a promising modality for screening of brain metastasis (1). Paramagnetic contrast media exhibits metastatic lesions as hyper-intensities on T1W images. Because blood vessels are also enhanced, it is important to suppress the blood signal in order to reduce potential misdiagnoses (2). Although this can be achieved by a 3...

متن کامل

Intravoxel Incoherent Motion in Normal Pituitary Gland: Initial Study with Turbo Spin-Echo Diffusion-Weighted Imaging.

BACKGROUND AND PURPOSE DWI with conventional single-shot EPI of the pituitary gland is hampered by strong susceptibility artifacts. Our purpose was to evaluate the feasibility of intravoxel incoherent motion assessment by using DWI based on TSE of the normal anterior pituitary lobe. MATERIALS AND METHODS The intravoxel incoherent motion parameters, including the true diffusion coefficient (D)...

متن کامل

Interpretation of tissue contrast in a rapid black-blood gradient echo sequence with motion-sensitized driven equilibrium (MSDE) preparation (3D MERGE) for 3D isotropic high-resolution imaging of the vessel wall and its application for hemorrhage detection

Fig 3. Intarplaque hemorrhage: Bright signal on TOF (yellow arrow) corresponds to hyperintensity on reformatted axial and sagittal 3D-MERGE images. Interpretation of tissue contrast in a rapid black-blood gradient echo sequence with motion-sensitized driven equilibrium (MSDE) preparation (3D MERGE) for 3D isotropic high-resolution imaging of the vessel wall and its application for hemorrhage de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 35 1  شماره 

صفحات  -

تاریخ انتشار 2014