Recording flow in the first second of a maximal forced expiratory manoeuvre: influence of frequency content.
نویسندگان
چکیده
The frequency content of the first second of the maximum forced expiratory manoeuvre (MFEM) was measured to determine if the currently accepted frequency limit of 20 Hz for MFEM is adequate for recording peak expiratory flow (PEF). The frequency response of a Fleisch pneumotachograph (PT) was measured and used to record MFEM from 24 patients attending a lung-function laboratory and 26 normal volunteers. The first 1.024 s of the signal recorded at 1,000 Hz for that blow with maximum PEF, underwent fast Fourier transformation using a triangular window function, applied after 0.75 s to reduce flow linearly to zero. All the frequencies above a set limit were removed, followed by inverse transformation to reconstitute the blow. The limits for this frequency cut-off were progressively varied from 100 Hz down to 15 Hz, with the resulting PEF being compared with the PEF from the reconstituted blow with no frequency reduction. The average+/-SD age for the group was 47+/-18 yrs and the average PEF was 450+/-187 L x min(-1), which, when expressed as a standardized residual, was 0.1+/-2.1, with a range from -4.5-3.9 indicating a good spread around normal values. Average rise time to PEF was 83+/-38 ms and dwell time >90% PEF was 45+/-25 ms. Cut-off >20 Hz reduced the mean PEF of the group by 8.5 L x min(-1) (95% confidence limit 5.5-11.4 L x min(-1)), whereas cut-off >30 Hz reduced mean PEF by 4.4 L x min(-1) (2.6-6.2). In the present study subjects, 30 Hz was on the 95th percentile of frequencies for defining the upper limit for 98% of the power spectrum for the first second of the blow. It has been shown that there are frequencies >20 Hz that contribute to peak expiratory flow enough to influence readings made using conventional hand-held peak expiratory flow meters, such as the mini-Wright. Devices used for recording flow from a maximum forced expiratory manoeuvre should therefore have an adequate frequency response of up to 30 Hz.
منابع مشابه
Dependence of forced vital capacity manoeuvre on time course of preceding inspiration in patients with restrictive lung disease.
In normal subjects and patients with airway obstruction, flows during a forced vital capacity (FVC) manoeuvre are higher after a fast inspiration without an end-inspiratory pause (manoeuvre 1) as compared to a slow inspiration with an end-expiratory pause of approximately 5 s (manoeuvre 2). In this study, we investigated the influence of these manoeuvres on maximal expiratory volume-time and fl...
متن کاملExpired air temperature at the mouth during a maximal forced expiratory manoeuvre.
We have studied the temperature of expired air during a maximal forced expiratory manoeuvre, because this has not previously been fully investigated and it will influence how flow and volume recording devices should be calibrated and used. Temperature was recorded with a fine thermocouple, the response time of which was determined at various gas velocities and for which a correction was made. R...
متن کاملDoes negative expiratory pressure influence performances of spirometry in older patients?
The aim of this study is to assess the influence of the negative expiratory pressure (NEP) technique on the performance of maximal expiratory manoeuvre in elderly patients. Firstly, the authors studied how NEP (at 5 and 10 cmH2O, NEP5 and NEP10) influences forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) in 60 young healthy volunteers, in order to assess the fluctua...
متن کاملThe influence of breathhold on peak expiratory flow in normal and asthmatic children.
We have previously demonstrated a 10% reduction in peak expiratory flow (PEF) in healthy adults following a breathhold at total lung capacity (TLC). This fall was attributed to dissipation of airway wall viscoelasticity, increasing airway wall compliance (Caw). To investigate this phenomenon in children and to determine whether the effect of breathhold would be greater in asthmatics than in nor...
متن کاملThe birth and development of the forced expiratory manoeuvre: a tribute to Robert Tiffeneau (1910-1961).
The forced expiratory manoeuvre was first described by Tiffeneau and Pinelli working in Paris (France), in December 1947, who proposed measurement of the "pulmonary capacity usable on exercise" (capacité pulmonaire utilisable à l'effort) (CPUE), the maximal volume expelled in one second after a deep inspiration. It was intended to replace the measurement of the maximum breathing capacity, a dif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 19 3 شماره
صفحات -