Evaluation of an in-situ output probe-microphone method for hearing aid fitting verification.
نویسندگان
چکیده
Several hearing aid prescription procedures specify frequency gain functions in terms of the desired levels of amplified speech. The most direct method for verifying hearing aid fittings based on these procedures requires a measurement of amplified speech in the ear canal. This paper describes the evaluation of a probe microphone measurement procedure designed to measure amplified speech to verify hearing aid fittings using the MSUv3 prescription procedure. With minor modifications, the same protocol could be used with other prescriptive procedures. Hearing aids were fitted to a group of subjects with sensorineural hearing impairment. Data derived from the fittings were analyzed to assess several issues relating to the procedure itself and to prescriptive fittings in general. The main results were: (1) with over the ear hearing aids, most prescriptions can be matched with an RMS error of 5 dB or less through the frequency range from 500 to 2500 Hz; (2) even though actual fittings usually do not perfectly correspond with their prescriptions, differences among frequency gain prescriptions are preserved in hearing aid fittings if the RMS error of the fitting is 5 dB or less; (3) if sound field stimuli presented to the hearing aid are precisely controlled, an in situ output verification method produces valid results; (4) when hearing aids are fitted with gain similar to that prescribed by the MSUv3 procedure, the maximum comfortable speech input level is typically about 72 dB; (5) the SSPL90 prescription generated by the MSUv3 procedure overestimates desired SSPL90 by 7 dB on average.
منابع مشابه
Trends In Amplification
©2003 Westminster Publications, Inc., 708 Glen Cove Avenue, Glen Head, NY 11545, U.S.A. Kuk and Ludvigsen (2003) present the argument that functional gain and, specifically, the behavioral measurement of “optimal” aided threshold, serves as an appropriate verification tool for fitting nonlinear hearing aids. This issue has been discussed for some time; Killion (1996) maintained that, “A good ar...
متن کاملTeleaudiology: evaluation of teleconsultation efficacy for hearing aid fitting.
PURPOSE To evaluate teleconsultation's efficacy for hearing aid fitting. METHODS Fifty hearing impaired individuals with ages ranging from 39 to 88 years and mean audiometric thresholds between 30 and 68.75 dBHL participated in this study. Participants were divided into two groups (stratified randomization): control group (n=25), submitted to face-to-face procedures, and experimental group (n...
متن کاملInitial-fit approach versus verified prescription: comparing self-perceived hearing aid benefit.
BACKGROUND Despite evidence suggesting inaccuracy in the default fittings provided by hearing aid manufacturers, the use of probe-microphone measures for the verification of fitting accuracy is routinely used by fewer than half of practicing audiologists. PURPOSE The present study examined whether self-perception of hearing aid benefit, as measured through the Abbreviated Profile of Hearing A...
متن کاملOpen fitting: performance verification of receiver in the ear and receiver in the aid.
OBJECTIVE To verify the receiver in the ear and receiver in the aid adaptations by measuring in situ the speech perception and users' level of satisfaction. METHODS The study was approved by the research ethics committee (Process: 027/2011). Twenty subjects older than 18 years with audiological diagnosis of mild and moderate bilateral descending sensorineural hearing loss were evaluated. The ...
متن کاملProbe-microphone measurements with body-worn instruments: loudspeaker and reference microphone effects.
Probe-microphone measurements are typically made with behind-the-ear (BTE) and in-the-ear (ITE) hearing aids with the loudspeaker located at 0-degrees or 45-degrees azimuth at head level and the reference microphone positioned on the head near the hearing aid microphone. With body-worn instruments, these conditions may not accurately reflect in situ hearing aid performance. This study compared ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ear and hearing
دوره 11 1 شماره
صفحات -
تاریخ انتشار 1990