Bi-level CPAP does not improve gas exchange when compared with conventional CPAP for the treatment of neonates recovering from respiratory distress syndrome.

نویسندگان

  • Andrea L Lampland
  • Brenda Plumm
  • Cathy Worwa
  • Patricia Meyers
  • Mark C Mammel
چکیده

AIM We hypothesised that short-term application of bi-level nasal continuous positive airway pressure CPAP (SiPAP) compared with conventional nasal CPAP (nCPAP) at the same mean airway pressure in infants with persistent oxygen need recovering from respiratory distress syndrome would improve CO2 removal with no change in oxygen requirement. DESIGN Non-blinded, randomised, observational four-period crossover study. SETTING/POPULATION Level III NICU; low-birthweight infants requiring CPAP and oxygen while recovering from respiratory distress syndrome. METHODS Infants requiring nasal CPAP for >24 h prior to study enrolment, and fraction of inspired oxygen requirement (FiO2) of 0.25-0.5, were randomised to either nCPAP or SiPAP. A crossover design with four 1 h treatment periods was used such that each infant received both treatments twice. Oxygen saturations (SaO2), transcutaneous CO2 (tcCO2) and vital signs were monitored continuously. Polysomnographic recordings were analysed for apnoea, bradycardia and oxygen desaturation. RESULTS Twenty low-birthweight infants receiving 0.3±0.04% supplemental oxygen on CPAP of 6 cm H2O were studied at an average of 33 days of age (±23 days, SD). There were no differences in tcCO2 or other physiological parameters except mean blood pressure, which was lower during nCPAP (52.3±8.3 vs 54.4±9.1 mm Hg; ±SD; p<0.01). No differences in short or prolonged apnoea, bradycardia or significant desaturation events were observed. CONCLUSIONS At similar mean airway pressures, SiPAP does not improve CO2 removal, oxygenation or other studied physiological parameters with the exception of mean blood pressure, which was not clinically significant. TRIAL REGISTRATION NUMBER NCT01053455.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Therapeutic Effects of Bubble CPAP and Ventilator CPAP on Respiratory Distress Syndrome in Premature Neonates

Background: Respiratory distress syndrome is one of the main complications associated with low birth weight, and a main cause of mortality in premature neonates. The present study aimed to compare the efficacy of ventilator continuous positive airway pressure (CPAP) and bubble CPAP in the treatment of respiratory distress syndrome (RDS) in premature neonates. Methods: This randomized controlled...

متن کامل

درمان زودرس با Nasal CPAP در نوزادان نارس با سندرم دیسترس تنفسی

Background: Respiratory distress syndrome (RDS) is a major cause of mortality among premature neonates. The present study was conducted to find out whether early nasal CPAP therapy could eliminate the need for mechanical ventilation in premature neonates with RDS. Materials and methods: For this clinical trial, premature neonates with RDS during the first 6 hours following the delivery were as...

متن کامل

Effect of Bubble and Ventilator-derived Continuous Positive Airway Pressure on the Management of Respiratory Distress Syndrome in Premature Neonates

Background: In this study, we aimed to compare ventilator-derived and bubble continuous positive airway pressure (CPAP) in neonates with respiratory distress syndrome admitted to Neonatal Intensive Care Unit of Vali-e-Asr Hospital, Birjand, Iran, in 2014. Methods: This cohort study was conducted among 68 patients assigned into two groups. The neonates in group A (32 infants) were treated with b...

متن کامل

Heated Humidified High-Flow Nasal Cannula Versus Nasal Continuous Positive Airway Pressure for the Facilitation of Extubation in Preterm Neonates with Respiratory Distress

Background: Heated humidified high-flow nasal cannula (HHHFNC) is gaining popularity as an alternative to nasal continuous positive airway pressure (nCPAP) therapy in the management of preterm neonates with respiratory distress due to ease of administration and patient comfort. However, limited evidence is available addressing its risks and benefits. To study the efficacy and safety of HHHFNC i...

متن کامل

Bi-level CPAP does not change central blood flow in preterm infants with respiratory distress syndrome

BACKGROUND Current literature provides limited data on the hemodynamic changes that may occur during bi-level continuous positive airway pressure (CPAP) support in preterm infants. However, the application of a positive end-expiratory pressure may be transmitted to the heart and the great vessels resulting in changes of central blood flow. OBJECTIVE To assess changes in central blood flow in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood. Fetal and neonatal edition

دوره 100 1  شماره 

صفحات  -

تاریخ انتشار 2015