EGSnrc Monte Carlo-aided dosimetric studies of the new BEBIG 60Co HDR brachytherapy source
نویسندگان
چکیده
PURPOSE The purpose of this study is to obtain the dosimetric parameters of the new BEBIG (60)Co brachytherapy source following by TG-43U1 recommendation with appropriate electron cutoff energy (0.521 MeV). MATERIAL AND METHODS The new BEBIG (60)Co brachytherapy source is used to calculate the TG-43U1 parameters. EGSnrc-based Monte Carlo simulation code has been used to calculate the radial dose functions and anisotropy functions. 2D dose rate table is obtained with Cartesian coordinate system for surrounding the source. RESULTS The radial dose functions are calculated for the distance of 0.06 cm to 100 cm from the source center with different cutoff energies and compared. The anisotropy functions values are calculated with the range of 1° to 179°, and apart from 0.2 cm to 20 cm of radial distances. The along-away dose rate data are calculated for quality assurance purposes. The calculated values are compared with the consensus data set and previous published results. CONCLUSIONS The radial dose function values from 0.06 cm to 0.16 cm are low, and these values gradually increased up to 0.3 cm radial distance. The radial dose function values are compared with the values of consensus data set using EGSnrc code system, and it is in good agreement with the published data range. The data for < 0.1 cm is not available in consensus data set, and extrapolated value is included for 0 distances which is the same as the value of 0.1 cm. In this study, the obtained values are strictly fall-off to < 0.1 cm distances. Good agreement with the published data was observed, except the values less than 40° angle at 0.5 cm distance for anisotropy function values.
منابع مشابه
Determination of TG-43 Dosimetric Parameters for Photon Emitting Brachytherapy Sources
Objective: Brachytherapy sources are widely used for the treatment of cancer. The report of Task Group No. 43 (TG-43) of American Association of Physicists in Medicine is known as the most common method for the determination of dosimetric parameters for brachytherapy sources. The aim of this study is to obtain TG-43 dosimetric parameters for 60Co, 137Cs, 192Ir and 103Pd brachyt...
متن کاملMonte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy
INTRODUCTION The use of high-dose-rate brachytherapy is currently a widespread practice worldwide. The most common isotope source is 192Ir, but 60Co is also becoming available for HDR. One of main advantages of 60Co compared to 192Ir is the economic and practical benefit because of its longer half-live, which is 5.27 years. Recently, Eckert & Ziegler BEBIG, Germany, introduced a new afterloadin...
متن کاملAccuracy Evaluation of Oncentraâ„¢ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code
Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...
متن کاملMonte Carlo calculation of the TG-43 dosimetric parameters of a new BEBIG Ir-192 HDR source.
BACKGROUND AND PURPOSE High dose rate (HDR) brachytherapy is a highly extended practice in clinical brachytherapy today. Quality dose rate distribution datasets of the HDR sources used in a clinical treatment are required. Because of the different source designs, a specific dosimetry dataset is required for each source model. In the recently published BRAPHYQS-ESTRO Report, an overview of avail...
متن کاملMonte Carlo Calculation of Beam Quality and Phantom Scatter Corrections for Lithium Formate Electron Paramagnetic Resonance Dosimeter for High-energy Brachytherapy Dosimetry
PURPOSE To investigate beam quality correction, KQQ0 (r) and phantom scatter correction, Kphan (r) for lithium formate dosimeter as a function of distance r along the transverse axis of the high-energy brachytherapy sources 60Co, 137Cs, 192Ir and 169Yb using the Monte Carlo-based EGSnrc code system. MATERIALS AND METHODS The brachytherapy sources investigated in this study are BEBIG High Dose...