Comparative analysis of the wear of titanium/ titanium and titanium/zirconia interfaces in implant/abutment assemblies after thermocycling and mechanical loading

نویسندگان

  • Paulo J. Almeida
  • Cesar L. Silva
  • Jorge L. Alves
  • Filipe S. Silva
  • Ramiro C. Martins
  • João Sampaio Fernandes
چکیده

Objectives: Due to its hardness, zirconia abutments may damage the titanium of the implant’s connection during its clinical use. This study aimed to assess the wear of the seating platforms of externally hexed titanium implants when connected to zirconia abutments comparing to titanium abutments, after thermocycling and mechanical loading (TCML). Methods: Six BNT® S4 external connection implants (Phibo® Dental Solutions, Barcelona, Spain) were selected and divided into two groups (n = 3): TiCE, screwed to titanium abutments and ZrCE, screwed to zirconia abutments. The samples underwent thermocycling (5000 cycles; 5–55 ◦C) and mechanical loading (1.2 × 106 cycles; 88.8 N; 4 Hz). Before and after TCML, the seating platforms of the implants were analyzed by 3D profilometry in two areas to measure their topography based on the superficial analysis parameters (Sa and Sz) parameters, and were studied by scanning electron microscopy (SEM). Data were statistically analyzed by Mann–Whitney test (p < 0.05). Results: No statistically significant differences were observed in the Sa and Sz values between the implants at initial state and after TCML (p = 0.573 > 0.05 and p = 0.059). The abutment’s material (titanium/zirconia) did not statistically significantly influence the Sa and Sz values after TCML (p = 0.886 > 0.05 and p = 0.200, respectively). However, the SEM analysis reveals a mild wear in some vertices of the hex when connected to zirconia abutments. Conclusions: After simulating five years of clinical use, the externally hexed implants, analyzed by 3D profilometry, showed similar wear patterns in the corresponding seating ∗ Corresponding author. E-mail address: [email protected] (P.J. Almeida). http://dx.doi.org/10.1016/j.rpemd.2016.07.002 1646-2890/© 2016 Sociedade Portuguesa de Estomatologia e Medicina Dentária. Published by Elsevier España, S.L.U. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Document downloaded from http://www.elsevier.es, day 29/07/2017. This copy is for personal use. Any transmission of this document by any media or format is strictly prohibited.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Evaluation of Microgap at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract   Background and Aim : Microgap in the implant-abutment interface is one of the main challenges in the treatment of two-piece implants. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microgap at implant-abutment interface area under oblique cyclic loading in vitro. Methods and Materials In this in vitro study, 12 implant-abutment assemb...

متن کامل

Comparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...

متن کامل

Evaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro

Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...

متن کامل

Wear at the titanium-zirconia implant-abutment interface: a pilot study.

PURPOSE The purpose of this study was to use a clinical simulation to determine whether wear of the internal surface of a titanium implant was greater following connection and loading of a one-piece zirconia implant abutment or a titanium implant abutment. MATERIALS AND METHODS Two implants received zirconia abutments and two received titanium abutments. The implants were secured into four fi...

متن کامل

مقایسه تشخیص رادیوگرافیک عدم تطابق اباتمنت‌‌های زیرکونیایی و تیتانیومی در سه نوع مختلف ناحیه اتصال

Background and Aims: In response to esthetic demand and use of zirconia abutments; detection of implant-abutment connection misfit is so important. The purpose of this study was to evaluate the sensitivity and specificity of radiographic images in the detection of abutment-implant connection misfit in zirconia and titanium abutments of three different implant connections. Materials and Met...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016