The reliability of making risk-based corrective action (RBCA) decisions using ASTM methods was evaluated. Indoor air quality (IAQ) testing results for 153 residential homes in 1998 at a site in Denver, Colo., were evaluated in this study. Decisions regarding groundwater remediation and indoor air mitigation in residences located over a shallow groundwater plume contaminated with chlorinated compounds were made based on actual test results. These decisions could have been based on the predicted concentrations of the compounds in indoor air using the Standard Guide for Risk-Based Corrective Action Applied at Petroleum Release Sites (ASTM E1739-95). Risk-based screening levels may be useful to guide general project decisions. However, variance of results from house to house is significant due to site-specific geological, building, and ventilation factors. Based on the results of this evaluation, indoor air quality testing should be used, rather than RBCA predictive modeling, to establish the extent of impacts and determine the need for mitigation.
منابع مشابه
Phytoforensics: Trees as bioindicators of potential indoor exposure via vapor intrusion
Human exposure to volatile organic compounds (VOCs) via vapor intrusion (VI) is an emerging public health concern with notable detrimental impacts on public health. Phytoforensics, plant sampling to semi-quantitatively delineate subsurface contamination, provides a potential non-invasive screening approach to detect VI potential, and plant sampling is effective and also time- and cost-efficient...
متن کاملThe Property Value Impacts of Groundwater Contamination:
There are few studies examining the impacts of groundwater quality on residential property values. Using a unique dataset of groundwater well tests, we link residential transactions to home-specific contamination levels and undertake a hedonic analysis of homes in Lake County, Florida; where groundwater pollution concerns stem primarily from agricultural runoff. We find that testing and contami...
متن کاملEvaluation of Air Quality in Buildings Located Above TCE and Chloroform Contaminated Plume - A Field Study
Vapor intrusion (VI) has been recognized since the 1990s as a potential pathway of concern at contaminated sites. VI is the migration of volatile organic compounds (VOCs) from the subsurface soils into overlying buildings. The major sources of organic vapors are waste disposal sites (landfills), contaminated old industrial sites, contaminated subsurface soils, and contaminated groundwater. The ...
متن کاملIndoor air mycoflora of residential dwellings in Jos metropolis.
BACKGROUND The quality of air in the environment where one lives or works can have potential effects on human health. There are strong indications that in many parts of the world, our homes, schools and workplaces are heavily contaminated with air-borne molds and other biological contaminants. OBJECTIVES This study was carried out to assess the level of fungal contamination of indoor air, hea...
متن کاملMicrobial contamination of indoor air due to leakages from crawl space: a field study.
Mechanical exhaust ventilation system is typical in apartment buildings in Finland. In most buildings the base floor between the first floor apartments and crawl space is not air tight. As the apartments have lower pressure than the crawl space due to ventilation, contaminated air may flow from the crawl space to the apartments. The object of this study was to find out whether a potential air f...
متن کامل