Correction: Evaluation of the Diagnostic Accuracy of Prototype Rapid Tests for Human African Trypanosomiasis
نویسندگان
چکیده
BACKGROUND Diagnosis of human African trypanosomiasis (HAT) remains a challenge both for active screening, which is critical in control of the disease, and in the point-of-care scenario where early and accurate diagnosis is essential. Recently, the first field deployment of a lateral flow rapid diagnostic test (RDT) for HAT, "SD BIOLINE HAT" has taken place. In this study, we evaluated the performance of "SD BIOLINE HAT" and two new prototype RDTs. METHODOLOGY/PRINCIPAL FINDINGS The performance of "SD BIOLINE HAT" and 2 prototype RDTs was tested using archived plasma from 250 Trypanosoma brucei gambiense patients, and 250 endemic controls. As well as comparison of the sensitivity and specificity of each device, the performance of individual antigens was assessed and the hypothetical performance of novel antigen combinations extrapolated. Neither of the prototype devices were inferior in sensitivity or specificity to "SD BIOLINE HAT" (sensitivity 0.82±0.01, specificity 0.97±0.01, 95% CI) at the 5% margins, while one of the devices (BBI) had significantly superior sensitivity (0.88±0.03). Analysis of the performance of individual antigens was used to model new antigen combinations to be explored in development of the next generation of HAT RDTs. The modelling showed that an RDT using two recombinant antigens (rLiTat1.5 and rISG65) would give a performance similar to the best devices in this study, and would also offer the most robust performance under deteriorating field conditions. CONCLUSIONS/SIGNIFICANCE Both "SD BIOLINE HAT" and the prototype devices performed comparably well to one another and also to the published performance range of the card agglutination test for trypanosomiasis in sensitivity and specificity. The performance of individual antigens enabled us to predict that an all-recombinant antigen RDT can be developed with an accuracy equivalent to " SD BIOLINE HAT." Such an RDT would have advantages in simplified manufacture, lower unit cost and assured reproducibility.
منابع مشابه
Sensitivity and Specificity of a Prototype Rapid Diagnostic Test for the Detection of Trypanosoma brucei gambiense Infection: A Multi-centric Prospective Study.
BACKGROUND A major challenge in the control of human African trypanosomiasis (HAT) is lack of reliable diagnostic tests that are rapid and easy to use in remote areas where the disease occurs. In Trypanosoma brucei gambiense HAT, the Card Agglutination Test for Trypanosomiasis (CATT) has been the reference screening test since 1978, usually on whole blood, but also in a 1/8 dilution (CATT 1/8) ...
متن کاملAccuracy of Individual Rapid Tests for Serodiagnosis of Gambiense Sleeping Sickness in West Africa
BACKGROUND Individual rapid tests for serodiagnosis (RDT) of human African trypanosomiasis (HAT) are particularly suited for passive screening and surveillance. However, so far, no large scale evaluation of RDTs has been performed for diagnosis of Trypanosoma brucei gambiense HAT in West Africa. The objective of this study was to assess the diagnostic accuracy of 2 commercial HAT-RDTs on stored...
متن کاملRapid diagnostic tests for neurological infections in central Africa.
Infections are a leading cause of life-threatening neuropathology worldwide. In central African countries affected by endemic diseases such as human African trypanosomiasis, tuberculosis, HIV/AIDS, and schistosomiasis, delayed diagnosis and treatment often lead to avoidable death or severe sequelae. Confirmatory microbiological and parasitological tests are essential because clinical features o...
متن کاملDiagnostic Accuracy of Molecular Amplification Tests for Human African Trypanosomiasis—Systematic Review
BACKGROUND A range of molecular amplification techniques have been developed for the diagnosis of Human African Trypanosomiasis (HAT); however, careful evaluation of these tests must precede implementation to ensure their high clinical accuracy. Here, we investigated the diagnostic accuracy of molecular amplification tests for HAT, the quality of articles and reasons for variation in accuracy. ...
متن کاملA new initiative for the development of new diagnostic tests for human African trypanosomiasis
Human African trypanosomiasis is a threat to millions of people living in sub-Saharan countries and is fatal unless treated. At present, the serological and parasitological tests used in the field for diagnosis of sleeping sickness have low specificity and sensitivity. There is clearly an urgent need for accurate tools for both diagnosis and staging of the disease. The Foundation for Innovative...
متن کامل