Diagnostic performance of the Roche AMPLICOR PCR in detecting Neisseria gonorrhoeae in genitourinary specimens from female sex workers in Cotonou, Benin.
نویسندگان
چکیده
The objective of this study was to evaluate the diagnostic performance of the Roche multiplex AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae PCR test for the detection of Neisseria gonorrhoeae infection in female urine specimens and wet and dry endocervical swabs. Endocervical swabs and urine specimens were collected from 342 female sex workers from Cotonou, Benin, and were tested using the AMPLICOR C. trachomatis/N. gonorrhoeae test (Roche Diagnostic Systems, Inc., Branchburg, N.J.) with internal control detection. Endocervical swabs were also cultured on Thayer-Martin medium. A series of alternate standards that included a combination of all the tests but not the test being evaluated was used to assess the performance of the test with each type of specimen. The sensitivity, specificity, and positive and negative predictive values for the urine were 53.8, 98.9, 93.5, and 87.5%, respectively. Corresponding figures for the wet swab were 91.5, 100, 100, and 97.4%, respectively. Those for the dry swab were 96.3, 96.2, 88.5, and 98.8%, respectively. Based on this study, the AMPLICOR PCR assay showed a low sensitivity for detection of N. gonorrhoeae infection in urine specimens, whereas the test was found to be highly sensitive and specific with endocervical specimens.
منابع مشابه
Evaluation of Abbott RealTime CT/NG Assay for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Cervical Swabs from Female Sex Workers in China
BACKGROUND To evaluate the performance of the Abbott RealTime CT/NG assay for detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) among female sex workers (FSWs) in China. METHODS Cervical swabs from 997 participants were blindly detected by the Abbott RealTime CT/NG assay on the automated m2000 molecular platform and Roche Cobas Amplicor CT/NG assay. Discrepant analysis we...
متن کاملAn assessment of the Roche Amplicor Chlamydia trachomatis/Neisseria gonorrhoeae multiplex PCR assay in routine diagnostic use on a variety of specimen types.
The Roche Cobas Amplicor Chlamydia trachomatis/Neisseria gonorrhoeae polymerase chain reaction (PCR) assay can simultaneously detect both C. trachomatis and N. gonorrhoeae, and has been cleared by United States Food and Drug Administration (FDA) for the testing of endocervical and urethral swabs and urine specimens. The Amplicor N. gonorrhoeae PCR target sequence is known to be present in some ...
متن کاملNeisseria species identification assay for the confirmation of Neisseria gonorrhoeae-positive results of the COBAS Amplicor PCR.
Screening assays for Neisseria gonorrhoeae exhibit low positive predictive values, particularly in low-prevalence populations. A new real-time PCR assay that detects and identifies individual Neisseria spp. using melt curve analysis was compared to two previously published supplementary assays. NsppID, a 16S rRNA real-time PCR/melt curve assay developed to distinguish N. gonorrhoeae from other ...
متن کاملEvaluation of conventional and real-time PCR assays using two targets for confirmation of results of the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae test for detection of Neisseria gonorrhoeae in clinical samples.
Two conventional PCR-enzyme immunoassays (PCR-EIAs) and two real-time PCR assays (LightCycler system; Roche Diagnostics) were evaluated as confirmation assays with cppB and 16S rRNA genes as targets. Of 765 male and female genitourinary and nasopharyngeal specimens positive for Neisseria gonorrhoeae in the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae PCR test (Roche Diagnostics), ...
متن کاملComparison between the LCx Probe system and the COBAS AMPLICOR system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae infections in patients attending a clinic for treatment of sexually transmitted diseases in Amsterdam, The Netherlands.
Two assays for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae were compared: the LCx Probe system (the LCx system; Abbott Diagnostic Laboratories, North Chicago, Ill.) and the COBAS AMPLICOR C. trachomatis/N. gonorrhoeae system (the COBAS AMPLICOR system; Roche Diagnostic Systems, Branchburg, N.J.). Endocervical swab specimens, male urethral swab specimens, and female and male...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 38 11 شماره
صفحات -
تاریخ انتشار 2000