Nonparametric Correction of Distortion 1 Nonparametric Correction of Distortion 1
نویسندگان
چکیده
Previous work on camera calibration, and particularly work on self-calibration, has assumed that the camera is well modeled by an ideal, relatively simple, parametric model. Real camera systems, however, diverge signiicantly from a simple pinhole perspective imaging model. Therefore, parametric calibration models are typically extended to include parameters which model distortions from perspective. However, tting these extra parameters greatly complicates calibration algorithms. This paper presents a new approach to camera calibration, which avoids elaborate parametric models. The imaging geometry of a camera is modeled by a 3 degree-of-freedom stereographic imaging model, together with a smooth distortion function D. D maps the raw camera output to the ideal model, subsuming the eeects of traditional parametric distortion parameters. The calibration algorithm reconstructs D from images of spheres, using the fact that spheres must appear circular in ideal stereographic projection. Accuracy and stability results for this algorithm are presented. The remaining free parameters (image center and focal length) can be estimated using several standard methods. New methods are presented for estimating the focal length (given the image center) using a single unknown image rotation and for pasting several images, taken by rotating the camera, into a panoramic image.
منابع مشابه
Nonparametric correction of distortion
Daniel E. Stevenson and Margaret M. Fleck Department of Computer Science, University of Iowa, Iowa City, IA 52242, USA [email protected], m [email protected] Abstract Images taken with wide-angle and inexpensive medium-angle lenses show substantial distortion, which will cause many computer vision applications to malfunction. Parametric calibration algorithms cannot handle the wide range of possi...
متن کاملNew approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras
Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...
متن کاملNonparametric , Model - Based Radial Lens Distortion Correction Using Tilted Camera Assumption ∗
Radial lens distortion prohibits use of simple pinhole camera models in computer vision applications, especially when using wide-angle lenses, which result in barreltype distortion. Usual approach to radial distortion is by the means of polynomial approximation, which introduces distortion-specific parameters into the camera model and requires iterative methods for their calculation. Based on t...
متن کاملA Novel Algorithm for the Correction of Eddy Current Distortion in Diffusion Weighted Imaging Data
Table 1. A comparison of valid tensors in the DTIs based on DWIs of different strategies of distortion correction. Our method provided the best result, while some other method may increase the number of ill-conditioned tensors (nonpositive definite). (a) (b) (c) (d) Figure 1. A comparison of distortion correction using different approaches. First Row: The simulated dataset; Second Row: The real...
متن کاملInvestigating the Factors Affecting Energy Consumption in the Iranian Agricultural Sector Using Parametric and Nonparametric Methods
Abstract In order to study energy consumption in Iran's agricultural sector, a Genetic algorithm concept was used to calculate significant factors affecting energy consumption between 1974 and 2008. Then, durability or "stability" of variables was assessed through econometric method (Augmented Dickey-Fuller test). In addition, long-term and short-term relationships of energy consumption were es...
متن کامل