Correction: Reliability and Validity of a Point-of-Care Sural Nerve Conduction Device for Identification of Diabetic Neuropathy
نویسندگان
چکیده
BACKGROUND Confirmation of diabetic sensorimotor polyneuropathy (DSP) relies on standard nerve conduction studies (NCS) performed in specialized clinics. We explored the utility of a point-of-care device (POCD) for DSP detection by nontechnical personnel and a validation of diagnostic thresholds with those observed in a normative database. RESEARCH DESIGN AND METHODS 44 subjects with type 1 and type 2 diabetes underwent standard NCS (reference method). Two nontechnical examiners measured sural nerve amplitude potential (SNAP) and conduction velocity (SNCV) using the POCD. Reliability was determined by intraclass correlation coefficients (ICC [2], [1]). Validity was determined by Bland-Altman analysis and receiver operating characteristic curves. RESULTS The 44 subjects (50% female) with mean age 56 ± 18 years had mean SNAP and SNCV of 8.0 ± 8.6 µV and 41.5 ± 8.2 m/s using standard NCS and 8.0 ± 8.2 µV and 49.9 ± 11.1 m/s using the POCD. Intrarater reproducibility ICC values were 0.97 for SNAP and 0.94 for SNCV while interrater reproducibility values were 0.83 and 0.79, respectively. Mean bias of the POCD was -0.1 ± 3.6 µV for SNAP and +8.4 ± 6.4 m/s for SNCV. A SNAP of ≤6 µV had 88% sensitivity and 94% specificity for identifying age-and height-standardized reference NCS values, while a SNCV of ≤48 m/s had 94% sensitivity and 82% specificity [corrected].. Abnormality in one or more of these thresholds was associated with 95% sensitivity and 71% specificity for identification of DSP according to electrophysiological criteria. CONCLUSIONS The POCD demonstrated excellent reliability and acceptable accuracy. Threshold values for DSP identification validated those of published POCD normative values. We emphasize the presence of measurement bias--particularly for SNCV--that requires adjustment of threshold values to reflect those of standard NCS.
منابع مشابه
مقایسه آثار درمان هشت هفتهای با فلوکستین و ایمیپرامین بر قند خون ناشتا در بیماران مبتلا به افسردگی
Background: Diabetic Neuropathy is the most common and troublesome complication of Diabetes Mellitus, leading to the greatest morbidity and mortality and resulting in a huge economic burden for diabetes care. Early diagnosis of distal symmetric sensorimotor polyneuropathy, a common complication of diabetes, may decrease morbidity by allowing potential therapeutic interventions.Methods: In 68 d...
متن کاملمقایسه معیارهای ارزیابی بالینی با یافتههای نوروفیزیولوژیک عصب سورال در تشخیص نوروپاتی بیماران مبتلا به دیابت
Background: Diabetic Neuropathy is the most common and troublesome complication of Diabetes Mellitus, leading to the greatest morbidity and mortality and resulting in a huge economic burden for diabetes care. Early diagnosis of distal symmetric sensorimotor polyneuropathy, a common complication of diabetes, may decrease morbidity by allowing potential therapeutic interventions. Methods: In 6...
متن کاملValidation of a novel point-of-care nerve conduction device for the detection of diabetic sensorimotor polyneuropathy.
OBJECTIVE The diagnosis of diabetic sensorimotor polyneuropathy using objective electrophysiological tests is hindered by limited access to the specialized laboratories and technicians that perform and interpret them. We evaluated the performance characteristics of a novel portable and automated point-of-care nerve conduction study device, which can be operated by nontechnical personnel, and co...
متن کاملEvaluation of sural nerve automated nerve conduction study in the diagnosis of peripheral neuropathy in patients with type 2 diabetes mellitus.
INTRODUCTION New tests for improved diagnosis of diabetic peripheral neuropathy (DPN) are useful. MATERIAL AND METHODS We evaluated the utility of automated nerve conduction study (NCS) of the sural nerve with a new portable device for the diagnosis of DPN in patients with type 2 diabetes mellitus (T2DM). This study included 114 T2DM patients (58 men) with mean age 64.60 ±8.61 years. Exclusio...
متن کاملStructure-function interactions in the therapeutic response of diabetic neuropathy.
Conventional electrophysiologic measurements such as nerve conduction velocity, compound action potential, and neuropathic symptom scores have been used to assess the severity of diabetic neuropathy and have been the major efficacy end points following pharmacologic intervention trials. Unfortunately, these measurements are not particularly sensitive and their reproducibility is, at best, good....
متن کامل