Improved success rates using videolaryngoscopy in unexperienced users: a randomized crossover study in airway manikins
نویسندگان
چکیده
BACKGROUND Videolaryngoscopy has been proven to be a safe procedure managing difficult airways in the hands of airway specialists. Information about the success rates in unexperienced users of videolaryngoscopy compared to conventional laryngoscopy is sparse. Therefore, we aimed to evaluate if there might be more success in securing an airway if the unexperienced provider is using a videolaryngoscope in simulated airways in a randomized manikin study. Differences between commonly used videolaryngoscopes were elucidated. METHODS A standardized hands-on workshop prior to the study was performed. For direct laryngoscopy (DL) we used a Macintosh laryngoscope, whereas for videolaryngoscopy (VL) we used the cMac, the dBlade, and a King Vision videolaryngoscope. Endotracheal intubations in three simulated normal and difficult airways were performed. Main outcome parameters were time to view and time to intubation. Cormack and Lehane (C + L) classification and the percentage of glottic opening (POGO) score were evaluated. After every intubation, the participants were asked to review the airway and the device used. RESULTS 22 participants (14.8 ± 4.0 intubations per year, mostly trauma surgeons) with limited experience in videolaryngoscopy (mean total number of videolaryngoscopy .4 ± .2) were enrolled. We found improved C + L grades with VL in contrast to DL. We saw similar data with respect to the POGO score, where the participants achieved better visibility of the glottis with VL. The hyperangulated blade geometries of videolaryngoscopes provided a better visibility in difficult airways than the standard geometry of the Macintosh-type blade. The subjective performance of the VL devices was better in more difficult airway scenarios. CONCLUSIONS After a short introduction and hands-on training, a videolaryngoscope seems to be safe and usable by unexperienced providers. We assume a standard geometry laryngoscope is optimal for a patient with normal anatomy, whereas VL device with a hyperangulated blade is ideal for difficult airway situations with limited mouth opening or restricted neck movement.
منابع مشابه
Combined Intubation Training (Simulated and Human) for 4th Year Medical Students: The Center for Advanced Technology and Telemedicine Airway Training Program
The video laryngoscope is a useful tool in intubation training as it allows both the trainer and the student to share the same view of the airway during the intubation process. In this study, the Center for Advanced Technology and Telemedicine's airway training program employed videolaryngoscopy (VL) in teaching both simulated (manikin) and human intubation. The videolaryngoscope statistically ...
متن کاملHands-Off Time for Endotracheal Intubation during CPR Is Not Altered by the Use of the C-MAC Video-Laryngoscope Compared to Conventional Direct Laryngoscopy. A Randomized Crossover Manikin Study
INTRODUCTION Sufficient ventilation and oxygenation through proper airway management is essential in patients undergoing cardio-pulmonary resuscitation (CPR). Although widely discussed, securing the airway using an endotracheal tube is considered the standard of care. Endotracheal intubation may be challenging and causes prolonged interruption of chest compressions. Videolaryngoscopes have been...
متن کاملComparison of GlideScope Videolaryngoscopy to Direct Laryngoscopy for Intubation of a Pediatric Simulator by Novice Physicians
Objective. To compare novice clinicians' performance using GlideScope videolaryngoscopy (GVL) to direct laryngoscopy (DL). Methods. This was a prospective, randomized crossover study. Incoming pediatric interns intubated pediatric simulators in four normal and difficult airway scenarios with GVL and DL. Primary outcomes included time to intubation and rate of successful intubation. Interns rate...
متن کاملEffects of an elevated position on time to tracheal intubation by novice intubators using Macintosh laryngoscopy or videolaryngoscopy: randomized crossover trial
OBJECTIVE To investigate the time to tracheal intubation using Glidescope videolaryngoscopy (GVL) compared to that of standard laryngoscopy, by using a Macintosh blade (SLM) in a human patient simulator in supine and elevated (ramped) positions. METHODS In this randomized crossover design, novice intubators (first-year medical students), using both laryngoscopic techniques, attempted tracheal...
متن کاملComparing McGRATH® MAC, C-MAC®, and Macintosh Laryngoscopes Operated by Medical Students: A Randomized, Crossover, Manikin Study
We hypothesized that the McGRATH MAC would decrease the time of intubation compared to C-MAC for novices. Thirty-nine medical students who had used the Macintosh blade to intubate a manikin fewer than 3 times were recruited. The participants performed sequential intubations on the manikin in two simulated settings that included a normal airway and a difficult airway (tongue edema). The intubati...
متن کامل