Prediction of the Transprosthetic Velocity Following Aortic Valve Replacement with Bioprosthesis in the Patients with Aortic Stenosis

نویسندگان

  • Yukio Umeda
  • Yasunari Yokota
  • Yoshio Mori
  • Yoko Kawamura
  • Hiroshi Takiya
چکیده

Method Twenty patients with AS without aortic insufficiency underwent AVR using bioprostheses were recruited. Preand post-AVR cardiac function parameters and aortic valve parameters were collected by transthoracic echocardiography. To evaluate the influences of peripheral vascular resistance on transvalvular flow velocity, static distensibility parameters of the carotid artery, such as b stiffness index, pressure-strain elastic modulus (Ep), and arterial compliance (AC), were obtained by a real time echo-tracking system at pre-AVR and 1 week after AVR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

Neo Left Main Channel Creation Using Double Stenting Alongside a Sapien 3 Aortic Valve Bioprosthesis for Left Main Coronary Obstruction Following Valve-in-Valve Transcatheter Aortic Valve Replacement: A Case Report With Review of Literature

Transcatheter aortic valve replacement in the setting of failed surgical bioprosthesis (valve-in-valve) is a valuable option for patients with bioprosthetic aortic stenosis or regurgitation who are deemed high risk for repeat open heart surgery. Although the procedure is successful with proper preprocedural assessment, instances of left main (LM) coronary artery ostium obstruction have been doc...

متن کامل

Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis.

OBJECTIVES This study was undertaken to compare the hemodynamic performance of a percutaneous bioprosthesis to that of surgically implanted (stented and stentless) bioprostheses for the treatment of severe aortic stenosis. METHODS Fifty patients who underwent percutaneous aortic valve implantation (PAVI) with the Cribier-Edwards or Edwards SAPIEN bioprosthetic valve (Edwards Lifesciences, Inc...

متن کامل

INFECTIVE ENDOCARDITIS IN CHILDREN

A total of 14 cases of infective endocarditis (IE) in children aged 6 months to 10 years were seen from December 1987 to December 1992 at the pediatric unit of Ayatollah Taleghani Medical Center. The majority of patients (12 of 14) were between 5 and 10 years of age. Acyanotic congenital heart disease was known to preexist in 78.6% and rheumatic valvular heart disease in 21.4% of cases. Or...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015